Dosimetric effects of small field size, dose grid size, and variable split-arc methods on gamma pass rates in radiation therapy
Radiological Physics and Technology · 2024
DOI: 10.1007/s12194-024-00809-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiological Physics and Technology, 2024. Verfasst von Tsunekazu Kuwae und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Yuuai Medical Center, Tomigusuku, Okinawa, Japan. cyunekazu@gmail.com. Hauptthemen laut MEDLINE: Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted, Radiometry, Gamma Rays. Die Arbeit nennt 8 Literaturangaben.
Abstract (Originalsprache)
This study investigates the influence of calculation accuracy in peripheral low-dose regions on the gamma pass rate (GPR), utilizing the Acuros XB (AXB) algorithm and ArcCHECK™ measurement. The effects of varying small field sizes, dose grid sizes, and split-arc techniques on GPR were analyzed. Various small field sizes were employed. Thirty-two single-arc plans with dose grid sizes of 2 mm and 1 mm and prescribed doses of 2, 5, 10, and 20 Gy were calculated using the AXB algorithm. In total, 128 GPR plans were examined. These plans were categorized into three sub-fields (3SF), four sub-fields (4SF), and six sub-fields (6SF). The GPR results deteriorated with smaller target sizes and a 2 mm dose grid size in a single arc. A similar degradation in GPR was observed with smaller target sizes and a 1 mm dose grid size. However, the 1 mm dose grid size generally resulted in better GPR compared with the 2 mm dose grid size for the same target sizes. The GPR improved with finer split angles and a 2 mm dose grid size in the split-arc method. However, no statistically significant improvement was observed with finer split angles and a 1 mm dose grid size. This study demonstrates that coarser dose grid sizes result in lower GPRs in peripheral low-dose regions as calculated by AXB with ArcCHECK™ measurement. To enhance GPR, employing split-arc methods and finer dose grid sizes could be beneficial.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Yuuai Medical Center, Tomigusuku, Okinawa, Japan. cyunekazu@gmail.com.
- Health Information Management Center, University of the Ryukyus Hospital, Nishihara, Okinawa, Japan.
- Department of Radiology, Yuuai Medical Center, Tomigusuku, Okinawa, Japan.
- Department of Radiology, Graduate School of Medicine, University of the Ryukyus, Nishihara, Okinawa, Japan.
Zitieren
APA
Kuwae, T., Ariga, T., Kusada, T., & Nishie, A. (2024). Dosimetric effects of small field size, dose grid size, and variable split-arc methods on gamma pass rates in radiation therapy. Radiological Physics and Technology. https://doi.org/10.1007/s12194-024-00809-7
Vancouver
Kuwae T, Ariga T, Kusada T, Nishie A. Dosimetric effects of small field size, dose grid size, and variable split-arc methods on gamma pass rates in radiation therapy. Radiological Physics and Technology. 2024. doi:10.1007/s12194-024-00809-7
BibTeX
@article{Kuwae2024,
author = {Kuwae, Tsunekazu and Ariga, Takuro and Kusada, Takeaki and Nishie, Akihiro},
title = {Dosimetric effects of small field size, dose grid size, and variable split-arc methods on gamma pass rates in radiation therapy},
journal = {Radiological Physics and Technology},
year = {2024},
doi = {10.1007/s12194-024-00809-7}
}
EUVIMED