Fully automatic online geometric calibration for non‐circular cone‐beam CT orbits using fiducials with unknown placement
Medical Physics · 2024
DOI: 10.1002/mp.17041 ↗At a glance
Journal article in Medical Physics, 2024. Written by Yiqun Q Ma and 7 co-authors. Institution: Johns Hopkins University, Baltimore, Maryland, USA. Major MEDLINE topics: Cone-Beam Computed Tomography, Algorithms. Cited 9 times so far (Crossref); 71 references. The full text is freely available in PubMed Central. Funded by: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.
Abstract (original language)
Background
Cone‐beam CT (CBCT) with non‐circular scanning orbits can improve image quality for 3D intraoperative image guidance. However, geometric calibration of such scans can be challenging. Existing methods typically require a prior image, specialized phantoms, presumed repeatable orbits, or long computation time.
Purpose
We propose a novel fully automatic online geometric calibration algorithm that does not require prior knowledge of fiducial configuration. The algorithm is fast, accurate, and can accommodate arbitrary scanning orbits and fiducial configurations.
Methods
The algorithm uses an automatic initialization process to eliminate human intervention in fiducial localization and an iterative refinement process to ensure robustness and accuracy. We provide a detailed explanation and implementation of the proposed algorithm. Physical experiments on a lab test bench and a clinical robotic C‐arm scanner were conducted to evaluate spatial resolution performance and robustness under realistic constraints.
Results
Qualitative and quantitative results from the physical experiments demonstrate high accuracy, efficiency, and robustness of the proposed method. The spatial resolution performance matched that of our existing benchmark method, which used a 3D‐2D registration‐based geometric calibration algorithm.
Conclusions
We have demonstrated an automatic online geometric calibration method that delivers high spatial resolution and robustness performance. This methodology enables arbitrary scan trajectories and should facilitate translation of such acquisition methods in a clinical setting.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Johns Hopkins University, Baltimore, Maryland, USA.
- Faculty of Medicine and Health, University of Sydney, Sydney, Australia.
- Siemens Healthineers, Forchheim, Germany.
- University of Pennsylvania, Philadelphia, USA.
ORCID profiles: Yiqun Q Ma
Funding
- NIBIB NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
Cite
APA
Ma, Y. Q., Reynolds, T., Ehtiati, T., Weiss, C., Hong, K., Theodore, N., Gang, G. J., & Stayman, J. W. (2024). Fully automatic online geometric calibration for non‐circular cone‐beam CT orbits using fiducials with unknown placement. Medical Physics. https://doi.org/10.1002/mp.17041
Vancouver
Ma YQ, Reynolds T, Ehtiati T, Weiss C, Hong K, Theodore N, et al. Fully automatic online geometric calibration for non‐circular cone‐beam CT orbits using fiducials with unknown placement. Medical Physics. 2024. doi:10.1002/mp.17041
BibTeX
@article{Ma2024,
author = {Ma, Yiqun Q and Reynolds, Tess and Ehtiati, Tina and Weiss, Clifford and Hong, Kelvin and Theodore, Nicholas and Gang, Grace J and Stayman, J Webster},
title = {Fully automatic online geometric calibration for non‐circular cone‐beam CT orbits using fiducials with unknown placement},
journal = {Medical Physics},
year = {2024},
doi = {10.1002/mp.17041}
}