Volumetric MRI with sparse sampling for MR‐guided 3D motion tracking via sparse prior‐augmented implicit neural representation learning

Lianli Liu, Liyue Shen, Adam Johansson, James M Balter, Yue Cao, Lucas Vitzthum, Lei Xing

Medical Physics · 2024

DOI: 10.1002/mp.16845 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Lianli Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Stanford University, Palo Alto, California, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Abdomen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NCI NIH HHS, NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Volumetric reconstruction of magnetic resonance imaging (MRI) from sparse samples is desirable for 3D motion tracking and promises to improve magnetic resonance (MR)‐guided radiation treatment precision. Data‐driven sparse MRI reconstruction, however, requires large‐scale training datasets for prior learning, which is time‐consuming and challenging to acquire in clinical settings.

Purpose

To investigate volumetric reconstruction of MRI from sparse samples of two orthogonal slices aided by sparse priors of two static 3D MRI through implicit neural representation (NeRP) learning, in support of 3D motion tracking during MR‐guided radiotherapy.

Methods

A multi‐layer perceptron network was trained to parameterize the NeRP model of a patient‐specific MRI dataset, where the network takes 4D data coordinates of voxel locations and motion states as inputs and outputs corresponding voxel intensities. By first training the network to learn the NeRP of two static 3D MRI with different breathing motion states, prior information of patient breathing motion was embedded into network weights through optimization. The prior information was then augmented from two motion states to 31 motion states by querying the optimized network at interpolated and extrapolated motion state coordinates. Starting from the prior‐augmented NeRP model as an initialization point, we further trained the network to fit sparse samples of two orthogonal MRI slices and the final volumetric reconstruction was obtained by querying the trained network at 3D spatial locations. We evaluated the proposed method using 5‐min volumetric MRI time series with 340 ms temporal resolution for seven abdominal patients with hepatocellular carcinoma, acquired using golden‐angle radial MRI sequence and reconstructed through retrospective sorting. Two volumetric MRI with inhale and exhale states respectively were selected from the first 30 s of the time series for prior embedding and augmentation. The remaining 4.5‐min time series was used for volumetric reconstruction evaluation, where we retrospectively subsampled each MRI to two orthogonal slices and compared model‐reconstructed images to ground truth images in terms of image quality and the capability of supporting 3D target motion tracking.

Results

Across the seven patients evaluated, the peak signal‐to‐noise‐ratio between model‐reconstructed and ground truth MR images was 38.02 ± 2.60 dB and the structure similarity index measure was 0.98 ± 0.01. Throughout the 4.5‐min time period, gross tumor volume (GTV) motion estimated by deforming a reference state MRI to model‐reconstructed and ground truth MRI showed good consistency. The 95‐percentile Hausdorff distance between GTV contours was 2.41 ± 0.77 mm, which is less than the voxel dimension. The mean GTV centroid position difference between ground truth and model estimation was less than 1 mm in all three orthogonal directions.

Conclusion

A prior‐augmented NeRP model has been developed to reconstruct volumetric MRI from sparse samples of orthogonal cine slices. Only one exhale and one inhale 3D MRI were needed to train the model to learn prior information of patient breathing motion for sparse image reconstruction. The proposed model has the potential of supporting 3D motion tracking during MR‐guided radiotherapy for improved treatment precision and promises a major simplification of the workflow by eliminating the need for large‐scale training datasets.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingAbdomenHumansRetrospective StudiesMotionRespirationMagnetic Resonance SpectroscopyImaging, Three-Dimensional

Stichwörter der Autor:innen

MR‐guided radiotherapydeep learningimage reconstructionmotion management

Autor:innen und Institutionen

  • Department of Radiation Oncology, Stanford University, Palo Alto, California, USA.
  • Department of Electrical Engineering, Stanford University, Palo Alto, California, USA.
  • Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan, USA.
  • Department of Immunology Genetics and pathology, Uppsala University, Uppsala, Sweden.
  • Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.

Förderung

  • NIH HHS
  • NCI NIH HHS
  • NIBIB NIH HHS
  • National Institutes of Health

Zitieren

APA

Liu, L., Shen, L., Johansson, A., Balter, J. M., Cao, Y., Vitzthum, L., & Xing, L. (2024). Volumetric MRI with sparse sampling for MR‐guided 3D motion tracking via sparse prior‐augmented implicit neural representation learning. Medical Physics. https://doi.org/10.1002/mp.16845

Vancouver

Liu L, Shen L, Johansson A, Balter JM, Cao Y, Vitzthum L, et al. Volumetric MRI with sparse sampling for MR‐guided 3D motion tracking via sparse prior‐augmented implicit neural representation learning. Medical Physics. 2024. doi:10.1002/mp.16845

BibTeX
@article{Liu2024,
  author = {Liu, Lianli and Shen, Liyue and Johansson, Adam and Balter, James M and Cao, Yue and Vitzthum, Lucas and Xing, Lei},
  title = {Volumetric MRI with sparse sampling for MR‐guided 3D motion tracking via sparse prior‐augmented implicit neural representation learning},
  journal = {Medical Physics},
  year = {2024},
  doi = {10.1002/mp.16845}
}
Kostenlos starten →