Journal article in Medical Physics, 2023. Written by Xinyang Zhang and 8 co-authors. Institution: Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China. Major MEDLINE topics: Deep Learning, Heavy Ion Radiotherapy. Cited 19 times so far (Crossref); 43 references. Funded by: National Key Research and Development Program of China, National Natural Science Foundation of China, Natural Science Foundation of Gansu Province.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Background

Plan verification is one of the important steps of quality assurance (QA) in carbon ion radiotherapy. Conventional methods of plan verification are based on phantom measurement, which is labor‐intensive and time‐consuming. Although the plan verification method based on Monte Carlo (MC) simulation provides a more accurate modeling of the physics, it is also time‐consuming when simulating with a large number of particles. Therefore, how to ensure the accuracy of simulation results while reducing simulation time is the current difficulty and focus.

Purpose

The purpose of this work was to evaluate the feasibility of using deep learning‐based MC denoising method to accelerate carbon‐ion radiotherapy plan verification.

Methods

Three models, including CycleGAN, 3DUNet and GhostUNet with Ghost module, were used to denoise the 1 × 10 6 carbon ions‐based MC dose distribution to the accuracy of 1 × 10 8 carbon ions‐based dose distribution. The CycleGAN's generator, 3DUNet and GhostUNet were all derived from the 3DUNet network. A total of 59 cases including 29 patients with head‐and‐neck cancers and 30 patients with lung cancers were collected, and 48 cases were randomly selected as the training set of the CycleGAN network and six cases as the test set. For the 3DUNet and GhostUNet models, the numbers of training set, validation set, and test set were 47, 6, and 6, respectively. Finally, the three models were evaluated qualitatively and quantitatively using RMSE and three‐dimensional gamma analysis (3 mm, 3%).

Results

The three end‐to‐end trained models could be used for denoising the 1 × 10 6 carbon ions‐based dose distribution, and their generalization was proved. The GhostUNet obtained the lowest RMSE value of 0.075, indicating the smallest difference between its denoised and 1 × 10 8 carbon ions‐based dose distributions. The average gamma passing rate (GPR) between the GhostUNet denoising‐based versus 1 × 10 8 carbon ions‐based dose distributions was 99.1%, higher than that of the CycleGAN at 94.3% and the 3DUNet at 96.2%. Among the three models, the GhostUNet model had the fewest parameters (4.27 million) and the shortest training time (99 s per epoch) but achieved the best denoising results.

Conclusion

The end‐to‐end deep network GhostUNet outperforms the CycleGAN, 3DUNet models in denoising MC dose distributions for carbon ion radiotherapy. The network requires less than 5 s to denoise a sample of MC simulation with few particles to obtain a qualitative and quantitative result comparable to the dose distribution simulated by MC with relatively large number particles, offering a significant reduction in computation time.

Subjects

MeSH terms (MEDLINE)

Deep LearningHeavy Ion RadiotherapyHumansRadiotherapy Planning, Computer-AssistedRadiotherapy DosageAlgorithmsIonsCarbonMonte Carlo Method

Author keywords

Monte Carlo simulationcarbon ion radiotherapydeep learninggamma passing rateplan verification

Substances

IonsCarbon

Authors and institutions

  • Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China.
  • Key Laboratory of Heavy Ion Radiation Biology and Medicine of Chinese Academy of Sciences, Lanzhou, China.
  • Key Laboratory of Basic Research on Heavy Ion Radiation Application in Medicine, Gansu Province, Lanzhou, China.
  • University of Chinese Academy of Sciences, Beijing, China.
  • Putian Lanhai Nuclear Medicine Research Center, Putian, China.
  • School of Nuclear Science and Technology, Lanzhou University, Lanzhou, China.

Funding

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China
  • Natural Science Foundation of Gansu Province
  • Special Project of Science and Technology Cooperation between Hubei Province and Chinese Academy of Sciences
  • National Basic Research Program of China

Cite

APA

Zhang, X., Zhang, H., Wang, J., Ma, Y., Liu, X., Dai, Z., He, R., He, P., & Li, Q. (2023). Deep learning‐based fast denoising of Monte Carlo dose calculation in carbon ion radiotherapy. Medical Physics. https://doi.org/10.1002/mp.16719

Vancouver

Zhang X, Zhang H, Wang J, Ma Y, Liu X, Dai Z, et al. Deep learning‐based fast denoising of Monte Carlo dose calculation in carbon ion radiotherapy. Medical Physics. 2023. doi:10.1002/mp.16719

BibTeX
@article{Zhang2023,
  author = {Zhang, Xinyang and Zhang, Hui and Wang, Jian and Ma, Yuanyuan and Liu, Xinguo and Dai, Zhongying and He, Rui and He, Pengbo and Li, Qiang},
  title = {Deep learning‐based fast denoising of Monte Carlo dose calculation in carbon ion radiotherapy},
  journal = {Medical Physics},
  year = {2023},
  doi = {10.1002/mp.16719}
}
Start for free →