Assessing the robustness of dose distributions in carbon ion prostate radiotherapy using a fast dose evaluation system
Journal of Applied Clinical Medical Physics · 2025
DOI: 10.1002/acm2.14528 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Toshiro Tsubouchi und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, Osaka Heavy Ion Therapy Center, Osaka, Japan. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Radiotherapy Planning, Computer-Assisted, Radiotherapy Dosage, Heavy Ion Radiotherapy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JSPS KAKENHI.
Abstract (Originalsprache)
Purpose
We developed a software program for swiftly calculating dose distributions for carbon ion beams. This study aims to evaluate the accuracy of dose calculations using this software and assess the robustness of dose distribution in treating prostate cancer.
Methods
At the Osaka Heavy Ion Therapy Center, markers are inserted into the prostate gland and used for position verification. To account for geometric changes along the beam path due to marker translation, a beam‐specific planning target volume (bsPTV) is set for each beam. To validate the accuracy of the dose calculations using the developed software, dose distributions for prostate and sarcoma cases were calculated and compared with the treatment planning system. To assess the robustness of the dose distribution, position verification data from 346 cases were utilized to reproduce dose distributions for three matching methods: bone matching, widely adopted in most particle therapy centers; marker translation, which involves direct translation to markers without bone matching; and marker translation after bone matching. The coverage of the target ( D 99 of clinical target volume (CTV)) was assessed to evaluate the robustness of the dose distribution. Additionally, statistical analyses were conducted for the dose distributions of each matching method.
Results
The dose calculation for a single condition can be completed very quickly. Statistical analysis revealed significant differences among dose distributions considering the three matching methods. When irradiation was performed with bone matching only, the D 99 was reduced by more than 10% in approximately 7.5% of cases, making it as the poorest among the three matching methods. However, there was no significant reduction in target coverage with the other two methods.
Conclusion
We have demonstrated the accuracy of the developed software for rapidly calculating dose distributions for carbon ion beams and confirmed the robustness of the dose distributions based on the bsPTV.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medical Physics, Osaka Heavy Ion Therapy Center, Osaka, Japan.
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka, Japan.
- RADLab Inc., Osaka, Japan.
- Department of Carbon Ion Radiotherapy, Osaka University Graduate School of Medicine, Osaka, Japan.
ORCID-Profile: Yuichi Akino
Förderung
- JSPS KAKENHI
Zitieren
APA
Tsubouchi, T., Shiomi, H., Suzuki, O., Hamatani, N., Takashina, M., Yagi, M., Wakisaka, Y., Ogawa, A., Terasawa, A., Akino, Y., Ogawa, K., & Kanai, T. (2025). Assessing the robustness of dose distributions in carbon ion prostate radiotherapy using a fast dose evaluation system. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14528
Vancouver
Tsubouchi T, Shiomi H, Suzuki O, Hamatani N, Takashina M, Yagi M, et al. Assessing the robustness of dose distributions in carbon ion prostate radiotherapy using a fast dose evaluation system. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.14528
BibTeX
@article{Tsubouchi2025,
author = {Tsubouchi, Toshiro and Shiomi, Hiroya and Suzuki, Osamu and Hamatani, Noriaki and Takashina, Masaaki and Yagi, Masashi and Wakisaka, Yushi and Ogawa, Atsuhiro and Terasawa, Ayumi and Akino, Yuichi and Ogawa, Kazuhiko and Kanai, Tatsuaki},
title = {Assessing the robustness of dose distributions in carbon ion prostate radiotherapy using a fast dose evaluation system},
journal = {Journal of Applied Clinical Medical Physics},
year = {2025},
doi = {10.1002/acm2.14528}
}
EUVIMED