CBCT‐Based synthetic CT image generation using conditional denoising diffusion probabilistic model
Medical Physics · 2024-03 · 51 (3) · 1847-1859
DOI: 10.1002/mp.16704 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, online erschienen am 30.08.2023. Verfasst von Junbo Peng und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Spiral Cone-Beam Computed Tomography. Die Arbeit wurde bisher 117-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NIDCR NIH HHS, NCI NIH HHS.
Abstract (Originalsprache)
Background
Daily or weekly cone‐beam computed tomography (CBCT) scans are commonly used for accurate patient positioning during the image‐guided radiotherapy (IGRT) process, making it an ideal option for adaptive radiotherapy (ART) replanning. However, the presence of severe artifacts and inaccurate Hounsfield unit (HU) values prevent its use for quantitative applications such as organ segmentation and dose calculation. To enable the clinical practice of online ART, it is crucial to obtain CBCT scans with a quality comparable to that of a CT scan.
Purpose
This work aims to develop a conditional diffusion model to perform image translation from the CBCT to the CT distribution for the image quality improvement of CBCT.
Methods
The proposed method is a conditional denoising diffusion probabilistic model (DDPM) that utilizes a time‐embedded U‐net architecture with residual and attention blocks to gradually transform the white Gaussian noise sample to the target CT distribution conditioned on the CBCT. The model was trained on deformed planning CT (dpCT) and CBCT image pairs, and its feasibility was verified in brain patient study and head‐and‐neck (H&N) patient study. The performance of the proposed algorithm was evaluated using mean absolute error (MAE), peak signal‐to‐noise ratio (PSNR) and normalized cross‐correlation (NCC) metrics on generated synthetic CT (sCT) samples. The proposed method was also compared to four other diffusion model‐based sCT generation methods.
Results
In the brain patient study, the MAE, PSNR, and NCC of the generated sCT were 25.99 HU, 30.49 dB, and 0.99, respectively, compared to 40.63 HU, 27.87 dB, and 0.98 of the CBCT images. In the H&N patient study, the metrics were 32.56 HU, 27.65 dB, 0.98 and 38.99 HU, 27.00, 0.98 for sCT and CBCT, respectively. Compared to the other four diffusion models and one Cycle generative adversarial network (Cycle GAN), the proposed method showed superior results in both visual quality and quantitative analysis.
Conclusions
The proposed conditional DDPM method can generate sCT from CBCT with accurate HU numbers and reduced artifacts, enabling accurate CBCT‐based organ segmentation and dose calculation for online ART.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
- Nuclear and Radiological Engineering and Medical physics Programs, George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA.
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
- Department of Radiation Oncology, Icahn School of Medicine at Mount Sinai, New York, New York, USA.
Förderung
- NIH HHS
- NIDCR NIH HHS
- NCI NIH HHS
- NIBIB NIH HHS
- National Institutes of Health
Zitieren
APA
Peng, J., Qiu, R. L. J., Wynne, J. F., Chang, C. W., Pan, S., Wang, T., Roper, J., Liu, T., Patel, P. R., Yu, D. S., & Yang, X. (2024). CBCT‐Based synthetic CT image generation using conditional denoising diffusion probabilistic model. Medical Physics, 51(3), 1847-1859. https://doi.org/10.1002/mp.16704
Vancouver
Peng J, Qiu RLJ, Wynne JF, Chang CW, Pan S, Wang T, et al. CBCT‐Based synthetic CT image generation using conditional denoising diffusion probabilistic model. Medical Physics. 2024;51(3):1847-1859. doi:10.1002/mp.16704
BibTeX
@article{Peng2024,
author = {Peng, Junbo and Qiu, Richard L J and Wynne, Jacob F and Chang, Chih-Wei and Pan, Shaoyan and Wang, Tonghe and Roper, Justin and Liu, Tian and Patel, Pretesh R and Yu, David S and Yang, Xiaofeng},
title = {CBCT‐Based synthetic CT image generation using conditional denoising diffusion probabilistic model},
journal = {Medical Physics},
year = {2024},
volume = {51},
number = {3},
pages = {1847--1859},
doi = {10.1002/mp.16704}
}
EUVIMED