Pseudo-medical image-guided technology based on 'CBCT-only' mode in esophageal cancer radiotherapy

Hongfei Sun, Zhi Yang, Jiarui Zhu, Jie Li, Jie Gong, Liting Chen, Zhongfei Wang, Yutian Yin, Ge Ren, Jing Cai, Lina Zhao

Computer Methods and Programs in Biomedicine · 2024

DOI: 10.1016/j.cmpb.2024.108007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2024. Verfasst von Hongfei Sun und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, Xi'an, China. Hauptthemen laut MEDLINE: Spiral Cone-Beam Computed Tomography, Radiotherapy, Image-Guided, Esophageal Neoplasms, Neuroectodermal Tumors, Primitive. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To minimize the various errors introduced by image-guided radiotherapy (IGRT) in the application of esophageal cancer treatment, this study proposes a novel technique based on the 'CBCT-only' mode of pseudo-medical image guidance.

Methods

The framework of this technology consists of two pseudo-medical image synthesis models in the CBCT→CT and the CT→PET direction. The former utilizes a dual-domain parallel deep learning model called AWM-PNet, which incorporates attention waning mechanisms. This model effectively suppresses artifacts in CBCT images in both the sinogram and spatial domains while efficiently capturing important image features and contextual information. The latter leverages tumor location and shape information provided by clinical experts. It introduces a PRAM-GAN model based on a prior region aware mechanism to establish a non-linear mapping relationship between CT and PET image domains. As a result, it enables the generation of pseudo-PET images that meet the clinical requirements for radiotherapy.

Results

The NRMSE and multi-scale SSIM (MS-SSIM) were utilized to evaluate the test set, and the results were presented as median values with lower quartile and upper quartile ranges. For the AWM-PNet model, the NRMSE and MS-SSIM values were 0.0218 (0.0143, 0.0255) and 0.9325 (0.9141, 0.9410), respectively. The PRAM-GAN model produced NRMSE and MS-SSIM values of 0.0404 (0.0356, 0.0476) and 0.9154 (0.8971, 0.9294), respectively. Statistical analysis revealed significant differences (p < 0.05) between these models and others. The numerical results of dose metrics, including D98 %, Dmean, and D2 %, validated the accuracy of HU values in the pseudo-CT images synthesized by the AWM-PNet. Furthermore, the Dice coefficient results confirmed statistically significant differences (p < 0.05) in GTV delineation between the pseudo-PET images synthesized using the PRAM-GAN model and other compared methods.

Conclusion

The AWM-PNet and PRAM-GAN models have the capability to generate accurate pseudo-CT and pseudo-PET images, respectively. The pseudo-image-guided technique based on the 'CBCT-only' mode shows promising prospects for application in esophageal cancer radiotherapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spiral Cone-Beam Computed TomographyRadiotherapy, Image-GuidedEsophageal NeoplasmsNeuroectodermal Tumors, PrimitiveHumansRadiotherapy Planning, Computer-AssistedCone-Beam Computed TomographyImage Processing, Computer-Assisted

Stichwörter der Autor:innen

CBCTEsophageal cancerIGRTPETPseudo-medical image synthesis

Autor:innen und Institutionen

  • Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, Xi'an, China.
  • Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China.
  • Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China. Electronic address: gary-ge.ren@polyu.edu.hk.
  • Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China. Electronic address: jing.cai@polyu.edu.hk.
  • Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, Xi'an, China. Electronic address: zhaolina@fmmu.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Sun, H., Yang, Z., Zhu, J., Li, J., Gong, J., Chen, L., Wang, Z., Yin, Y., Ren, G., Cai, J., & Zhao, L. (2024). Pseudo-medical image-guided technology based on 'CBCT-only' mode in esophageal cancer radiotherapy. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2024.108007

Vancouver

Sun H, Yang Z, Zhu J, Li J, Gong J, Chen L, et al. Pseudo-medical image-guided technology based on 'CBCT-only' mode in esophageal cancer radiotherapy. Computer Methods and Programs in Biomedicine. 2024. doi:10.1016/j.cmpb.2024.108007

BibTeX
@article{Sun2024,
  author = {Sun, Hongfei and Yang, Zhi and Zhu, Jiarui and Li, Jie and Gong, Jie and Chen, Liting and Wang, Zhongfei and Yin, Yutian and Ren, Ge and Cai, Jing and Zhao, Lina},
  title = {Pseudo-medical image-guided technology based on 'CBCT-only' mode in esophageal cancer radiotherapy},
  journal = {Computer Methods and Programs in Biomedicine},
  year = {2024},
  doi = {10.1016/j.cmpb.2024.108007}
}
Kostenlos starten →