EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Self‐supervised denoising of projection data for low‐dose cone‐beam CT

Kihwan Choi iD, Seung Hyoung Kim iD, Sungwon Kim iD

Medical Physics · 2023

DOI: 10.1002/mp.16421 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2023. Verfasst von Kihwan Choi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Bionics Research Center, Korea Institute of Science and Technology, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Neural Networks, Computer. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Korea Institute of Science and Technology, Korea Medical Device Development Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Convolutional neural networks (CNNs) have shown promising results in image denoising tasks. While most existing CNN‐based methods depend on supervised learning by directly mapping noisy inputs to clean targets, high‐quality references are often unavailable for interventional radiology such as cone‐beam computed tomography (CBCT).

Purpose

In this paper, we propose a novel self‐supervised learning method that reduces noise in projections acquired by ordinary CBCT scans.

Methods

With a network that partially blinds input, we are able to train the denoising model by mapping the partially blinded projections to the original projections. Additionally, we incorporate noise‐to‐noise learning into the self‐supervised learning by mapping the adjacent projections to the original projections. With standard image reconstruction methods such as FDK‐type algorithms, we can reconstruct high‐quality CBCT images from the projections denoised by our projection‐domain denoising method.

Results

In the head phantom study, we measure peak signal‐to‐noise ratio (PSNR) and structural similarity index measure (SSIM) values of the proposed method along with the other denoising methods and uncorrected low‐dose CBCT data for a quantitative comparison both in projection and image domains. The PSNR and SSIM values of our self‐supervised denoising approach are 27.08 and 0.839, whereas those of uncorrected CBCT images are 15.68 and 0.103, respectively. In the retrospective study, we assess the quality of interventional patient CBCT images to evaluate the projection‐domain and image‐domain denoising methods. Both qualitative and quantitative results indicate that our approach can effectively produce high‐quality CBCT images with low‐dose projections in the absence of duplicate clean or noisy references.

Conclusions

Our self‐supervised learning strategy is capable of restoring anatomical information while efficiently removing noise in CBCT projection data.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyNeural Networks, ComputerHumansRetrospective StudiesAlgorithmsImage Processing, Computer-AssistedPhantoms, Imaging

Stichwörter der Autor:innen

cone-beam CTdose reductionmodel fusionprojection-domain denoisingself-supervised learning

Autor:innen und Institutionen

  • Bionics Research Center, Korea Institute of Science and Technology, Seoul, Republic of Korea.
  • Department of Radiology, Yonsei University College of Medicine, Seoul, Republic of Korea.

ORCID-Profile: Kihwan Choi, Seung Hyoung Kim, Sungwon Kim

Förderung

  • Korea Institute of Science and Technology
  • Korea Medical Device Development Fund

Zitieren

APA

Choi, K., Kim, S. H., & Kim, S. (2023). Self‐supervised denoising of projection data for low‐dose cone‐beam CT. Medical Physics. https://doi.org/10.1002/mp.16421

Vancouver

Choi K, Kim SH, Kim S. Self‐supervised denoising of projection data for low‐dose cone‐beam CT. Medical Physics. 2023. doi:10.1002/mp.16421

BibTeX
@article{Choi2023,
  author = {Choi, Kihwan and Kim, Seung Hyoung and Kim, Sungwon},
  title = {Self‐supervised denoising of projection data for low‐dose cone‐beam CT},
  journal = {Medical Physics},
  year = {2023},
  doi = {10.1002/mp.16421}
}