EUVIMEDEUVIMED entdecken
Crossref

Geometric parameters sensitivity evaluation based on projection trajectories for X-ray cone-beam computed laminography

Yanmin Sun, Yu Han, Siyu Tan, Xiaoqi Xi, Lei Li, Bin Yan, Yuan Zhang

Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · 15.03.2023 · 31 (2) · 423-434

DOI: 10.3233/xst-221338 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics, online erschienen am 06.02.2023. Verfasst von Yanmin Sun und 6 weiteren Autor:innen. Beteiligte Einrichtung: Henan Key Laboratory of Imaging and Intelligent Processing, PLA Strategy Support Force Information Engineering University, Zhengzhou, Henan, China. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: X-ray cone-beam computed laminography (CL) is widely used for large flat objects that computed tomography (CT) cannot investigate. The rotation angle of axis tilt makes geometric correction of CL system more complicated and has more uncertain factors. Therefore, it is necessary to evaluate sensitivity of the geometric parameters of CL system in advance. OBJECTIVE: This study aims to objectively and comprehensively evaluate sensitivity of CL geometric parameters based on the projection trajectory. METHODS: This study proposes the Minimum Deviation Unit (MDU) to evaluate sensitivity of CL geometric parameters. First, the projection trajectory formulas are derived according to the spatial relationship of CL system geometric parameters. Next, the MDU of the geometric parameters is obtained based on the projection trajectories and used as the evaluation index to measure the sensitivity of parameters. Then, the influence of the rotation angle of the axis tilt and magnification on the MDU of the parameters is analyzed. RESULTS: At low magnification, three susceptible parameters ( η, u 0 , v 0 ) with MDU less than 1 (° or mm) must be calibrated accurately to avoid geometric artifacts. The sensitivity of CL parameters increases as the magnification increases, and all parameters become highly sensitive when the magnification power is greater than 10. CONCLUSION: The results of this study have important guiding significance for the subsequent further parameter calibration.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyImage Processing, Computer-AssistedX-RaysAlgorithmsPhantoms, Imaging

Stichwörter der Autor:innen

Cone-beamX-ray laminographycomputed laminographygeometric parametersparameters sensitivitysensitivity evaluation

Autor:innen und Institutionen

  • Henan Key Laboratory of Imaging and Intelligent Processing, PLA Strategy Support Force Information Engineering University, Zhengzhou, Henan, China.
  • College of Information Science and Engineering, Henan University of Technology, Zhengzhou, Henan, China.

Zitieren

APA

Sun, Y., Han, Y., Tan, S., Xi, X., Li, L., Yan, B., & Zhang, Y. (2023). Geometric parameters sensitivity evaluation based on projection trajectories for X-ray cone-beam computed laminography. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics, 31(2), 423-434. https://doi.org/10.3233/xst-221338

Vancouver

Sun Y, Han Y, Tan S, Xi X, Li L, Yan B, et al. Geometric parameters sensitivity evaluation based on projection trajectories for X-ray cone-beam computed laminography. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. 2023;31(2):423-434. doi:10.3233/xst-221338

BibTeX
@article{Sun2023,
  author = {Sun, Yanmin and Han, Yu and Tan, Siyu and Xi, Xiaoqi and Li, Lei and Yan, Bin and Zhang, Yuan},
  title = {Geometric parameters sensitivity evaluation based on projection trajectories for X-ray cone-beam computed laminography},
  journal = {Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics},
  year = {2023},
  volume = {31},
  number = {2},
  pages = {423--434},
  doi = {10.3233/xst-221338}
}
Kostenlos starten →