EUVIMEDDescobrir EUVIMED
Open access

Robust quantification of CT‐ventilation biomarker techniques and repeatability in a porcine model

Mattison J Flakus, Antonia E Wuschner, Eric M Wallat, Wei Shao, Jen Meudt, Dhanansayan Shanmuganayagam, Gary E Christensen, Joseph M Reinhardt, John E Bayouth

Medical Physics · 2023

DOI: 10.1002/mp.16400 ↗

At a glance

Journal article in Medical Physics, 2023. Written by Mattison J Flakus and 8 co-authors. Institution: Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA. Major MEDLINE topics: Lung Neoplasms. Cited 5 times so far (Crossref); 43 references. The full text is freely available in PubMed Central. Funded by: NIDDK NIH HHS, NCI NIH HHS, NIH HHS.

ResumoSubjectsDados bibliográficosCiteRelated studies

Abstract (original language)

Background

Biomarkers estimating local lung ventilation have been derived from computed tomography (CT) imaging using various image acquisition and post‐processing techniques. CT‐ventilation biomarkers have potential clinical use in functional avoidance radiation therapy (RT), in which RT treatment plans are optimized to reduce dose delivered to highly ventilated lung. Widespread clinical implementation of CT‐ventilation biomarkers necessitates understanding of biomarker repeatability. Performing imaging within a highly controlled experimental design enables quantification of error associated with remaining variables.

Purpose

To characterize CT‐ventilation biomarker repeatability and dependence on image acquisition and post‐processing methodology in anesthetized and mechanically ventilated pigs.

Methods

Five mechanically ventilated Wisconsin Miniature Swine (WMS) received multiple consecutive four‐dimensional CT (4DCT) and maximum inhale and exhale breath‐hold CT (BH‐CT) scans on five dates to generate CT‐ventilation biomarkers. Breathing maneuvers were controlled with an average tidal volume difference

Subjects

MeSH terms (MEDLINE)

Lung NeoplasmsHumansSwineAnimalsPulmonary VentilationRespirationLungFour-Dimensional Computed TomographyBiomarkers

Author keywords

biomarkersrepeatabilityventilation

Substances

Biomarkers

Authors and institutions

  • Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
  • Department of Medicine, University of Florida, Gainesville, Florida, USA.
  • Department of Animal and Dairy Sciences, University of Wisconsin-Madison, Madison, Wisconsin, USA.
  • Department of Surgery, University of Wisconsin-Madison, Madison, Wisconsin, USA.
  • Department of Electrical and Computer Engineering, University of Iowa, Iowa City, Iowa, USA.
  • Department of Radiation Oncology, University of Iowa, Iowa City, Iowa, USA.

Funding

  • NIDDK NIH HHS
  • NCI NIH HHS
  • NIH HHS
  • National Institutes of Health

Cite

APA

Flakus, M. J., Wuschner, A. E., Wallat, E. M., Shao, W., Meudt, J., Shanmuganayagam, D., Christensen, G. E., Reinhardt, J. M., & Bayouth, J. E. (2023). Robust quantification of CT‐ventilation biomarker techniques and repeatability in a porcine model. Medical Physics. https://doi.org/10.1002/mp.16400

Vancouver

Flakus MJ, Wuschner AE, Wallat EM, Shao W, Meudt J, Shanmuganayagam D, et al. Robust quantification of CT‐ventilation biomarker techniques and repeatability in a porcine model. Medical Physics. 2023. doi:10.1002/mp.16400

BibTeX
@article{Flakus2023,
  author = {Flakus, Mattison J and Wuschner, Antonia E and Wallat, Eric M and Shao, Wei and Meudt, Jen and Shanmuganayagam, Dhanansayan and Christensen, Gary E and Reinhardt, Joseph M and Bayouth, John E},
  title = {Robust quantification of CT‐ventilation biomarker techniques and repeatability in a porcine model},
  journal = {Medical Physics},
  year = {2023},
  doi = {10.1002/mp.16400}
}
Start for free →