Robust quantification of CT‐ventilation biomarker techniques and repeatability in a porcine model
Medical Physics · 2023
DOI: 10.1002/mp.16400 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2023. Verfasst von Mattison J Flakus und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA. Hauptthemen laut MEDLINE: Lung Neoplasms. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDDK NIH HHS, NCI NIH HHS, NIH HHS.
Abstract (Originalsprache)
Background
Biomarkers estimating local lung ventilation have been derived from computed tomography (CT) imaging using various image acquisition and post‐processing techniques. CT‐ventilation biomarkers have potential clinical use in functional avoidance radiation therapy (RT), in which RT treatment plans are optimized to reduce dose delivered to highly ventilated lung. Widespread clinical implementation of CT‐ventilation biomarkers necessitates understanding of biomarker repeatability. Performing imaging within a highly controlled experimental design enables quantification of error associated with remaining variables.
Purpose
To characterize CT‐ventilation biomarker repeatability and dependence on image acquisition and post‐processing methodology in anesthetized and mechanically ventilated pigs.
Methods
Five mechanically ventilated Wisconsin Miniature Swine (WMS) received multiple consecutive four‐dimensional CT (4DCT) and maximum inhale and exhale breath‐hold CT (BH‐CT) scans on five dates to generate CT‐ventilation biomarkers. Breathing maneuvers were controlled with an average tidal volume difference
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Medicine, University of Florida, Gainesville, Florida, USA.
- Department of Animal and Dairy Sciences, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Surgery, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Electrical and Computer Engineering, University of Iowa, Iowa City, Iowa, USA.
- Department of Radiation Oncology, University of Iowa, Iowa City, Iowa, USA.
Förderung
- NIDDK NIH HHS
- NCI NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Flakus, M. J., Wuschner, A. E., Wallat, E. M., Shao, W., Meudt, J., Shanmuganayagam, D., Christensen, G. E., Reinhardt, J. M., & Bayouth, J. E. (2023). Robust quantification of CT‐ventilation biomarker techniques and repeatability in a porcine model. Medical Physics. https://doi.org/10.1002/mp.16400
Vancouver
Flakus MJ, Wuschner AE, Wallat EM, Shao W, Meudt J, Shanmuganayagam D, et al. Robust quantification of CT‐ventilation biomarker techniques and repeatability in a porcine model. Medical Physics. 2023. doi:10.1002/mp.16400
BibTeX
@article{Flakus2023,
author = {Flakus, Mattison J and Wuschner, Antonia E and Wallat, Eric M and Shao, Wei and Meudt, Jen and Shanmuganayagam, Dhanansayan and Christensen, Gary E and Reinhardt, Joseph M and Bayouth, John E},
title = {Robust quantification of CT‐ventilation biomarker techniques and repeatability in a porcine model},
journal = {Medical Physics},
year = {2023},
doi = {10.1002/mp.16400}
}