EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Evaluation of a calibration rig for stereo laparoscopes

Thomas Dowrick, Guofang Xiao, Daniil Nikitichev, Eren Dursun, Niels van Berkel, Moustafa Allam, Bongjin Koo, Joao Ramalhinho, Stephen Thompson, Kurinchi Gurusamy, Ann Blandford, Danail Stoyanov and 2 more

Medical Physics · 2023

DOI: 10.1002/mp.16310 ↗

At a glance

Journal article in Medical Physics, 2023. Written by Thomas Dowrick and 13 co-authors. Institution: Wellcome EPSRC Centre for Interventional and Surgical Sciences, UCL, London, UK. Major MEDLINE topics: Laparoscopes, Image Processing, Computer-Assisted, Calibration. Cited 8 times so far (Crossref); 40 references. The full text is freely available (open access, CC BY 4.0). Funded by: Wellcome Trust, Engineering and Physical Sciences Research Council, NIHR Biomedical Research Centre, Royal Marsden NHS Foundation Trust/Institute of Cancer Research.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Accurate camera and hand‐eye calibration are essential to ensure high‐quality results in image‐guided surgery applications. The process must also be able to be undertaken by a nonexpert user in a surgical setting.

Purpose

This work seeks to identify a suitable method for tracked stereo laparoscope calibration within theater.

Methods

A custom calibration rig, to enable rapid calibration in a surgical setting, was designed. The rig was compared against freehand calibration. Stereo reprojection, stereo reconstruction, tracked stereo reprojection, and tracked stereo reconstruction error metrics were used to evaluate calibration quality.

Results

Use of the calibration rig reduced mean errors: reprojection (1.47 mm [SD 0.13] vs. 3.14 mm [SD 2.11], p ‐value 1e−8), reconstruction (1.37 px [SD 0.10] vs. 10.10 px [SD 4.54], p ‐value 6e−7), and tracked reconstruction (1.38 mm [SD 0.10] vs. 12.64 mm [SD 4.34], p ‐value 1e−6) compared with freehand calibration. The use of a ChArUco pattern yielded slightly lower reprojection errors, while a dot grid produced lower reconstruction errors and was more robust under strong global illumination.

Conclusion

The use of the calibration rig results in a statistically significant decrease in calibration error metrics, versus freehand calibration, and represents the preferred approach for use in the operating theater.

Subjects

MeSH terms (MEDLINE)

LaparoscopesImage Processing, Computer-AssistedCalibrationLaparoscopyData AccuracyOptical Devices

Author keywords

calibrationimage-guided surgerylaparascopestereo

Authors and institutions

  • Wellcome EPSRC Centre for Interventional and Surgical Sciences, UCL, London, UK.
  • Royal Free Campus, UCL Medical School, Royal Free Hospital, London, UK.

Funding

  • Wellcome Trust
  • Engineering and Physical Sciences Research Council
  • NIHR Biomedical Research Centre, Royal Marsden NHS Foundation Trust/Institute of Cancer Research

Cite

APA

Dowrick, T., Xiao, G., Nikitichev, D., Dursun, E., van Berkel, N., Allam, M., Koo, B., Ramalhinho, J., Thompson, S., Gurusamy, K., Blandford, A., Stoyanov, D., Davidson, B. R., & Clarkson, M. J. (2023). Evaluation of a calibration rig for stereo laparoscopes. Medical Physics. https://doi.org/10.1002/mp.16310

Vancouver

Dowrick T, Xiao G, Nikitichev D, Dursun E, van Berkel N, Allam M, et al. Evaluation of a calibration rig for stereo laparoscopes. Medical Physics. 2023. doi:10.1002/mp.16310

BibTeX
@article{Dowrick2023,
  author = {Dowrick, Thomas and Xiao, Guofang and Nikitichev, Daniil and Dursun, Eren and van Berkel, Niels and Allam, Moustafa and Koo, Bongjin and Ramalhinho, Joao and Thompson, Stephen and Gurusamy, Kurinchi and Blandford, Ann and Stoyanov, Danail and Davidson, Brian R and Clarkson, Matthew J},
  title = {Evaluation of a calibration rig for stereo laparoscopes},
  journal = {Medical Physics},
  year = {2023},
  doi = {10.1002/mp.16310}
}
Start for free →