Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 22.05.2026. Verfasst von Christos Koutserimpas und 6 weiteren Autor:innen. Beteiligte Einrichtung: Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Hospices Civ…. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: None.
Abstract (Originalsprache)
Purpose
Total knee arthroplasty (TKA) after anterior cruciate ligament reconstruction (ACLR) is technically demanding and has been associated with higher complication rates. This study aimed to evaluate whether patients with prior ACLR undergoing image‐based robotic‐assisted TKA performed under functional alignment (FA) principles achieve comparable clinical outcomes and early implant survivorship to patients undergoing primary TKA without previous ligament surgery.
Methods
This retrospective comparative study (between March 2021 and December 2023) included consecutive patients who underwent image‐based robotic‐assisted TKA under FA principles with a minimum 24‐month follow‐up. Patients were divided into those with prior ACLR (study group) and those without previous ligament surgery (control group). Demographics, radiographic alignment, robotic implant positioning, knee society scores (KSS), forgotten joint score (FJS), active knee flexion, complications and all‐cause revision rates were analysed. Kaplan–Meier survival analysis was performed.
Results
A total of 383 TKAs were included (45 ACLR, 338 controls). Patients with prior ACLR were younger (62 vs. 70 years, p < 0.0001) and had lower BMI (25.34 vs. 28.32 kg/m², p < 0.0001). Postoperatively, KSS‐knee (95 [interquartile range, IQR] 88–100) vs. 94 [90–100], p = 0.79], KSS‐function (90 [89.5–100] vs. 90 [90–100], p = 0.82) and FJS (83 [63–94] vs. 86 [67–94], p = 0.80) were comparable between groups. Active knee flexion was lower in the ACLR group (120° [112.5–130] vs. 130° [120–130], p = 0.048). Overall complication rates were 15.6% versus 9.2% ( p = 0.18). All‐cause revision rates were 2.2% versus 1.5% ( p = 0.70). Kaplan–Meier analysis demonstrated no difference in implant survivorship (HR = 1.62, 95% CI 0.13–19.57, p = 0.70).
Conclusion
Robotic‐assisted TKA performed under FA principles provides comparable patient‐reported outcomes and early implant survivorship in patients with prior ACLR and those undergoing standard primary TKA, although a modest reduction in postoperative knee flexion persists in the ACLR subgroup. Level of Evidence Level III.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Hospices Civils de Lyon, Lyon, France.
- School of Health Rehabilitation Sciences, University of Patras, Patras, Greece.
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy.
- Sezione di Chirurgia Protesica ad Indirizzo Robotico - Unità di Traumatologia Dello Sport, Ortopedia e Traumatologia, Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy.
- Fondazione Policlinico Universitario Campus Bio-Medico, Roma, Italy.
- LIBM-EA 7424, Interuniversity Laboratory of Biology of Mobility, Claude Bernard Lyon 1 University Lyon, Lyon, France.
ORCID-Profile: Christos Koutserimpas
Förderung
- None
Zitieren
APA
Koutserimpas, C., De Fazio, A., Andriollo, L., Gregori, P., Servien, E., Batailler, C., & Lustig, S. (2026). Prior anterior cruciate ligament reconstruction: Comparable outcomes but reduced knee flexion after robotic functionally aligned total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.70463
Vancouver
Koutserimpas C, De Fazio A, Andriollo L, Gregori P, Servien E, Batailler C, et al. Prior anterior cruciate ligament reconstruction: Comparable outcomes but reduced knee flexion after robotic functionally aligned total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy. 2026. doi:10.1002/ksa.70463
BibTeX
@article{Koutserimpas2026,
author = {Koutserimpas, Christos and De Fazio, Andrea and Andriollo, Luca and Gregori, Pietro and Servien, Elvire and Batailler, Cécile and Lustig, Sébastien},
title = {Prior anterior cruciate ligament reconstruction: Comparable outcomes but reduced knee flexion after robotic functionally aligned total knee arthroplasty},
journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
year = {2026},
doi = {10.1002/ksa.70463}
}
EUVIMED