EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparable clinical outcomes but different postoperative Dynamic Alignment of the Knee (DyAK) patterns between cruciate‐retaining and posterior‐stabilized inserts in functionally aligned robotic‐assisted total knee arthroplasty

Christos Koutserimpas iD, Enejd Veizi, Sébastien Lustig, Konstantinos Dretakis

Journal of Experimental Orthopaedics · 2026-10 · 13 (4)

DOI: 10.1002/jeo2.70963 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Experimental Orthopaedics, online erschienen am 28.10.2026. Verfasst von Christos Koutserimpas und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Health Rehabilitation Sciences University of Patras Patras Greece. Die Arbeit nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The influence of polyethylene insert design during robotic‐assisted total knee arthroplasty (TKA) performed according to functional alignment (FA) principles remains poorly understood. This study compared cruciate‐retaining (CR) and posterior‐stabilized (PS) inserts with respect to implant positioning, clinical outcomes, implant survivorship and postoperative dynamic knee behaviour using the Dynamic Alignment of the Knee (DyAK) classification.

Methods

A retrospective comparative study was performed on 284 primary functionally aligned robotic‐assisted TKAs. The cohort comprised 148 CR and 136 PS fixed‐bearing cemented implants with a minimum follow‐up of 3 years (median 44.5 months). Clinical outcomes included Knee Society Score (KSS) and Forgotten Joint Score (FJS). Intraoperative robotic implant positioning, bone resections, polyethylene thickness, DyAK classification, complications and Kaplan–Meier implant survivorship were compared between groups.

Results

The CR group demonstrated greater preoperative varus alignment (median robotic hip–knee–ankle angle [rHKA] 5° vs. 3°, p = 0.01). Compared with PS implants, CR inserts were implanted with greater tibial varus (2° vs. 1°, p < 0.0001), greater posterior tibial slope (3° vs. 1°, p < 0.0001) and slightly greater femoral external rotation ( p = 0.009). Polyethylene inserts >9 mm were required more frequently in the PS group (39.0% vs. 15.5%, p < 0.0001). At final follow‐up, KSS knee ( p = 0.56), KSS function ( p = 0.62) and FJS ( p = 0.06) were comparable between groups. No statistically significant difference in survivorship was detected for aseptic loosening (0.68% vs. 0.74%, p = 0.95) and all‐cause revision (2.03% vs. 1.47%, p = 0.72). The DyAK classification changed significantly more frequently in the PS group than in the CR group (69.9% vs. 52.7%, p = 0.003), despite similar postoperative clinical outcomes.

Conclusion

CR and PS polyethylene inserts showed no significant differences in final clinical scores or implant survivorship at a minimum follow‐up of 3 years but demonstrated different patterns of postoperative dynamic alignment, suggesting that the DyAK classification may provide complementary information beyond conventional outcome measures. Level of Evidence Level III.

Schlagwörter

Stichwörter der Autor:innen

Dynamic Alignment of the KneeTKAfunctional knee positioningpersonalized alignmentrobotic knee

Autor:innen und Institutionen

  • School of Health Rehabilitation Sciences University of Patras Patras Greece.
  • 2nd Department of Orthopaedic Surgery Hygeia Hospital of Athens Marousi Greece.
  • Department of Orthopedic Surgery Aspetar Orthopedic and Sports Medicine Hospital Doha Qatar.
  • Department of Orthopedics and Traumatology Ankara Yıldırım Beyazıt University Ankara Turkey.
  • Orthopaedics Surgery and Sports Medicine Department FIFA Medical Center of Excellence Croix-Rousse Hospital, Hospices Civils de Lyon, Lyon North University Hospital Lyon France.
  • Université de Lyon, Université Gustave Eiffel, Université Claude Bernard Lyon 1 Lyon France.

ORCID-Profile: Christos Koutserimpas

Zitieren

APA

Koutserimpas, C., Veizi, E., Lustig, S., & Dretakis, K. (2026). Comparable clinical outcomes but different postoperative Dynamic Alignment of the Knee (DyAK) patterns between cruciate‐retaining and posterior‐stabilized inserts in functionally aligned robotic‐assisted total knee arthroplasty. Journal of Experimental Orthopaedics, 13(4). https://doi.org/10.1002/jeo2.70963

Vancouver

Koutserimpas C, Veizi E, Lustig S, Dretakis K. Comparable clinical outcomes but different postoperative Dynamic Alignment of the Knee (DyAK) patterns between cruciate‐retaining and posterior‐stabilized inserts in functionally aligned robotic‐assisted total knee arthroplasty. Journal of Experimental Orthopaedics. 2026;13(4). doi:10.1002/jeo2.70963

BibTeX
@article{Koutserimpas2026,
  author = {Koutserimpas, Christos and Veizi, Enejd and Lustig, Sébastien and Dretakis, Konstantinos},
  title = {Comparable clinical outcomes but different postoperative Dynamic Alignment of the Knee (DyAK) patterns between cruciate‐retaining and posterior‐stabilized inserts in functionally aligned robotic‐assisted total knee arthroplasty},
  journal = {Journal of Experimental Orthopaedics},
  year = {2026},
  volume = {13},
  number = {4},
  doi = {10.1002/jeo2.70963}
}
Kostenlos starten →