EUVIMEDEUVIMED entdecken
Crossref

Functionally aligned total knee arthroplasty: A lateral flexion laxity up to 6 mm is safe!

Jeremy Nixon, Baha John Tadros iD, Ignacio Moreno-Suarez, William Pretty, Dermot Collopy, Gavin Clark

Knee Surgery, Sports Traumatology, Arthroscopy · 2024-05 · 32 (5) · 1317-1323

DOI: 10.1002/ksa.12087 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 21.03.2024. Verfasst von Jeremy Nixon und 5 weiteren Autor:innen. Beteiligte Einrichtung: St John of God Hospital Subiaco and Midland Hospitals, Subiaco, Western Australia, Australia. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Range of Motion, Articular, Joint Instability, Patient Reported Outcome Measures. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: St John of God Healthcare, Osborne Park, Western Australia, Australia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Loose flexion gaps are associated with poor functional outcomes and instability in total knee arthroplasty (TKA). The effect of a trapezoidal flexion gap in a functionally aligned TKA remains unknown. The aim of this study was to investigate the effect of a larger lateral flexion gap in a robotic‐assisted (RA), functionally aligned (FA) and cruciate‐retaining (CR) TKA on clinical outcomes.

Methods

Data from 527 TKA in 478 patients from 2018 to 2020 were collected. All patients underwent an RA (MAKO, Stryker), FA and CR TKA. Gap measurements were collected intraoperatively. Patient‐reported outcome measures (PROMs), pain Visual analogue score (VAS) and range of motion were collected postoperatively. Patients were also asked about the ease of stair ascent and descent and kneeling on a 5‐point scale. The minimum follow‐up was 2 years. Patients were stratified into three groups based on lateral flexion laxity.

Results

At 2 years postoperatively, the group with a looser gap (3–6 mm) had higher mean PROMs when compared with the group with a gap of 2–3 mm. There were no differences detected in any other outcomes at 2 years. A total of 70.9% of patients in the group with a 3–6 mm gap reported being able to walk down a flight of stairs 'easily', compared with 56.7% in the 2–3 mm group and 54% in the

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRange of Motion, ArticularJoint InstabilityPatient Reported Outcome MeasuresHumansFemaleMaleAgedMiddle AgedRobotic Surgical ProceduresRetrospective StudiesOsteoarthritis, Knee

Stichwörter der Autor:innen

functional alignmentgap balancingoutcomesrobotic‐assistedtotal knee arthroplasty

Autor:innen und Institutionen

  • St John of God Hospital Subiaco and Midland Hospitals, Subiaco, Western Australia, Australia.
  • Perth Hip and Knee Clinic, Subiaco, Western Australia, Australia.
  • University of Western Australia, Crawley, Western Australia, Australia.

ORCID-Profile: Baha John Tadros

Förderung

  • St John of God Healthcare, Osborne Park, Western Australia, Australia

Zitieren

APA

Nixon, J., Tadros, B. J., Moreno-Suarez, I., Pretty, W., Collopy, D., & Clark, G. (2024). Functionally aligned total knee arthroplasty: A lateral flexion laxity up to 6 mm is safe!. Knee Surgery, Sports Traumatology, Arthroscopy, 32(5), 1317-1323. https://doi.org/10.1002/ksa.12087

Vancouver

Nixon J, Tadros BJ, Moreno-Suarez I, Pretty W, Collopy D, Clark G. Functionally aligned total knee arthroplasty: A lateral flexion laxity up to 6 mm is safe!. Knee Surgery, Sports Traumatology, Arthroscopy. 2024;32(5):1317-1323. doi:10.1002/ksa.12087

BibTeX
@article{Nixon2024,
  author = {Nixon, Jeremy and Tadros, Baha John and Moreno-Suarez, Ignacio and Pretty, William and Collopy, Dermot and Clark, Gavin},
  title = {Functionally aligned total knee arthroplasty: A lateral flexion laxity up to 6 mm is safe!},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2024},
  volume = {32},
  number = {5},
  pages = {1317--1323},
  doi = {10.1002/ksa.12087}
}