EUVIMEDEUVIMED entdecken
Open Access

Smaller medial component gaps at deep flexion are associated with better patient‐reported outcomes after robotic‐assisted cruciate‐retaining total knee arthroplasty using an anatomically designed implant

Yutaka Nakamura iD, Hiroyasu Ogawa iD, Yusuke Ota, Kaito Takagi, Masaya Sengoku, Kazuichiro Onishi, Haruhiko Akiyama

Knee Surgery, Sports Traumatology, Arthroscopy · 2026-09 · 34 (9) · 3348-3361

DOI: 10.1002/ksa.70214 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 07.12.2025. Verfasst von Yutaka Nakamura und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Gifu University Graduate School of Medicine, Gifu, Gifu, Japan. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Patient Reported Outcome Measures, Robotic Surgical Procedures, Knee Prosthesis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Soft tissue balance is essential for optimal function and satisfaction after total knee arthroplasty (TKA). However, the clinical significance of medial gap patterns across the entire range of motion (ROM) remains unclear. This study aimed to examine the association between intraoperative medial gap patterns and post‐operative patient‐reported outcome measures (PROMs) in robotic‐assisted cruciate‐retaining (CR) TKA. It was hypothesized that medial gap patterns with smaller deep‐flexion gaps relative to mid‐flexion or 90° flexion would be associated with superior PROMs.

Methods

This retrospective study included 102 patients (120 knees) who underwent primary robotic‐assisted CR TKA. Bone and cartilage resection thickness and simulated gaps were assessed at the planning stage, and the final component gaps were recorded at the trial stage. Medial gap patterns were classified as: 1 (constant), 2 (gradually increasing), 3 (increasing/decreasing) and 4 (gradually decreasing). Objective outcomes were assessed using the Knee Society Score (KSS), and subjective outcomes were evaluated using the Western Ontario and McMaster Universities Arthritis Index (WOMAC), Forgotten Joint Score‐12 and the satisfaction score of the 2011 KSS.

Results

Ten, 47, 51 and 12 knees were classified into Patterns 1–4, respectively. The resection gaps at flexion and the flexion–extension gap difference were relatively larger in Pattern 2. Objective outcomes were comparable among patterns; however, the PROMs differed significantly. Pattern 3 demonstrated better WOMAC stiffness and KSS satisfaction scores than Patterns 1 and 2.

Conclusion

Medial gap patterns in which deep‐flexion gaps did not exceed those at mid‐flexion or 90° flexion were associated with better PROMs in robotic‐assisted CR TKA. These findings support the hypothesis that avoiding underestimation of native joint gaps at deep flexion is important for optimizing patient‐reported outcomes. Level of Evidence Level III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneePatient Reported Outcome MeasuresRobotic Surgical ProceduresKnee ProsthesisOsteoarthritis, KneeHumansFemaleRetrospective StudiesRange of Motion, ArticularMaleAgedMiddle AgedProsthesis DesignKnee JointAged, 80 and overTreatment Outcome

Stichwörter der Autor:innen

component gapkinematic alignmentpatient‐reported outcome measuresrobotic‐assistedtotal knee arthroplasty

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Gifu University Graduate School of Medicine, Gifu, Gifu, Japan.
  • Department of Orthopedic Surgery, Ogaki Tokushukai Hospital, Ogaki, Gifu, Japan.

ORCID-Profile: Yutaka Nakamura, Hiroyasu Ogawa

Zitieren

APA

Nakamura, Y., Ogawa, H., Ota, Y., Takagi, K., Sengoku, M., Onishi, K., & Akiyama, H. (2026). Smaller medial component gaps at deep flexion are associated with better patient‐reported outcomes after robotic‐assisted cruciate‐retaining total knee arthroplasty using an anatomically designed implant. Knee Surgery, Sports Traumatology, Arthroscopy, 34(9), 3348-3361. https://doi.org/10.1002/ksa.70214

Vancouver

Nakamura Y, Ogawa H, Ota Y, Takagi K, Sengoku M, Onishi K, et al. Smaller medial component gaps at deep flexion are associated with better patient‐reported outcomes after robotic‐assisted cruciate‐retaining total knee arthroplasty using an anatomically designed implant. Knee Surgery, Sports Traumatology, Arthroscopy. 2026;34(9):3348-3361. doi:10.1002/ksa.70214

BibTeX
@article{Nakamura2026,
  author = {Nakamura, Yutaka and Ogawa, Hiroyasu and Ota, Yusuke and Takagi, Kaito and Sengoku, Masaya and Onishi, Kazuichiro and Akiyama, Haruhiko},
  title = {Smaller medial component gaps at deep flexion are associated with better patient‐reported outcomes after robotic‐assisted cruciate‐retaining total knee arthroplasty using an anatomically designed implant},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2026},
  volume = {34},
  number = {9},
  pages = {3348--3361},
  doi = {10.1002/ksa.70214}
}
Kostenlos starten →