EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An Asymmetric Medio-Lateral Flexion Laxity Target Yields Excellent Results in Robotic-Assisted Total Knee Arthroplasty With Functional Knee Positioning

Hannes Vermue, Francesco Zambianchi, Sebastiano Clemenza, Mattia Clò, Jan Victor, Fabio Catani

The Journal of Arthroplasty · 2026-08 · 41 (8) · 2411-2417.e1

DOI: 10.1016/j.arth.2025.11.030 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2026-08. Verfasst von Hannes Vermue und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery and Traumatology, Ghent University Hospital, Ghent, Belgium. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Joint Instability, Robotic Surgical Procedures, Knee Joint. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Functional knee positioning (FKP) in robotic-assisted (RA) total knee arthroplasty (TKA) aims to optimize soft-tissue balance through patient-specific implant fine-tuning. However, it remains unclear (1) how intraoperative ligament laxity affects joint awareness and (2) whether the discrepancy between intraoperative planned and achieved laxity is affected by preoperative coronal limb alignment or fixed flexion deformity (FFD). METHODS: This retrospective study analyzed 130 patients undergoing image-based RA TKA with FKP using a cementless cruciate-retaining implant. Intraoperative adjustments were made to balance the flexion-extension laxity, targeting one to two mm larger lateral flexion laxity. Medial and lateral gaps before and after implant positioning were recorded at near extension and 90° flexion. Patient-reported outcome measures (PROMs), including the Forgotten Joint Score (FJS-12) and a 5-point Likert scale for satisfaction, were assessed at a minimum of one year postoperatively to investigate correlations between PROMs and final intraoperative laxities. The impact of preoperative coronal limb alignment, measured on long-leg radiographs, and FFD on final laxities was also evaluated. RESULTS: Final laxities were: median medial extension laxity 1.5 mm (1.0 to 2.0), lateral extension laxity 1.5 mm (1.1 to 2.0), medial flexion laxity 1.0 mm (0.5 to 1.5), and lateral flexion laxity 2.0 mm (1.5 to 2.5). At one year, the FJS-12 was 87.4 ± 14.5. A weak inverse correlation was observed between medial flexion laxity and FJS-12 (r = -0.18, P = 0.047); no other laxities were associated with PROMs. Sensitivity analyses showed no relevant laxity cutoffs influencing PROMs. Valgus knees exhibited larger changes between planned and final medial extension laxity compared with varus knees (P 10° showed no discrepancy between planned and final extension laxities (P < 0.003). CONCLUSIONS: Image-based RA TKA using FKP achieves good-to-excellent clinical outcomes at one year, with a balanced symmetric extension laxity. Coronal limb alignment and FFD significantly influence the deviation between planned and final extension laxity and should be considered during surgical planning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeJoint InstabilityRobotic Surgical ProceduresKnee JointOsteoarthritis, KneeHumansRetrospective StudiesAgedFemaleRange of Motion, ArticularMiddle AgedMaleAged, 80 and overKnee ProsthesisTreatment OutcomePatient Reported Outcome Measures

Stichwörter der Autor:innen

functionallaxityligament balancerobotic-assistedtotal knee arthroplasty

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery and Traumatology, Ghent University Hospital, Ghent, Belgium.
  • Department of Orthopaedics and Traumatology, Azienda Ospedaliero-Universitaria di Modena, Università degli Studi di Modena e Reggio-Emilia, Modena, Italy.
  • Department of Orthopaedics and Traumatology, Azienda Ospedaliero-Universitaria di Modena, Università degli Studi di Modena e Reggio-Emilia, Modena, Italy; Department of Orthopaedic Surgery, School of Medicine, Universit…

Zitieren

APA

Vermue, H., Zambianchi, F., Clemenza, S., Clò, M., Victor, J., & Catani, F. (2026). An Asymmetric Medio-Lateral Flexion Laxity Target Yields Excellent Results in Robotic-Assisted Total Knee Arthroplasty With Functional Knee Positioning. The Journal of Arthroplasty, 41(8), 2411-2417.e1. https://doi.org/10.1016/j.arth.2025.11.030

Vancouver

Vermue H, Zambianchi F, Clemenza S, Clò M, Victor J, Catani F. An Asymmetric Medio-Lateral Flexion Laxity Target Yields Excellent Results in Robotic-Assisted Total Knee Arthroplasty With Functional Knee Positioning. The Journal of Arthroplasty. 2026;41(8):2411-2417.e1. doi:10.1016/j.arth.2025.11.030

BibTeX
@article{Vermue2026,
  author = {Vermue, Hannes and Zambianchi, Francesco and Clemenza, Sebastiano and Clò, Mattia and Victor, Jan and Catani, Fabio},
  title = {An Asymmetric Medio-Lateral Flexion Laxity Target Yields Excellent Results in Robotic-Assisted Total Knee Arthroplasty With Functional Knee Positioning},
  journal = {The Journal of Arthroplasty},
  year = {2026},
  volume = {41},
  number = {8},
  pages = {2411--2417.e1},
  doi = {10.1016/j.arth.2025.11.030}
}
Kostenlos starten →