EUVIMEDEUVIMED entdecken
Systematische ÜbersichtÜbersichtsarbeitOpen Access

There is no standardised measurement approach for medial proximal tibial angle after unicompartmental knee arthroplasty: A systematic review

Sina Hajiaghajani, Ali Soltani Farsani, Sina Aminizadeh, Mohammad Poursalehian, Abtin Alvand, Seyed Mohammad Javad Mortazavi iD

Knee Surgery, Sports Traumatology, Arthroscopy · 2026-09 · 34 (9) · 3322-3332

DOI: 10.1002/ksa.70204 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 01.12.2025. Verfasst von Sina Hajiaghajani und 5 weiteren Autor:innen. Beteiligte Einrichtung: Joint Reconstruction Research Center, Tehran University of Medical Sciences, Tehran, Iran. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Tibia, Osteoarthritis, Knee, Knee Joint. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Unicompartmental knee arthroplasty (UKA) is increasingly used for isolated knee osteoarthritis. The medial proximal tibial angle (MPTA) is important for describing tibial alignment. However, MPTA measurement after UKA is challenging because one tibial compartment is prosthetic. This systematic review evaluated the measurement of MPTA after UKA, summarised methodological variability, and assessed the quality and reliability of the reported methods.

Methods

PubMed, Embase, Web of Science, and Scopus were searched. Eligible original studies reported radiographic MPTA measurement techniques in patients who underwent UKA. Two reviewers independently screened, extracted data, and assessed study quality using the Newcastle–Ottawa Scale. Due to methodological heterogeneity, a qualitative narrative synthesis was conducted.

Results

Twenty‐three studies met the inclusion criteria, encompassing 4,075 patients and one cadaveric study with 26 specimens. Measurement reporting was heterogeneous and often incomplete: 12 studies did not specify their MPTA technique. Among the described approaches, three standard methods emerged: (1) using the tibial component coronal angle (TCA) as a proxy for MPTA, (2) connecting the proximal medial point of the prosthesis to a lateral native tibial landmark (medial‐to‐lateral joint line), and (3) the Cartier‐type angle. Reliability reporting was limited: only six studies reported both inter‐ and intra‐observer reliability with specific statistical measures, three reported inter‐observer reliability only, three stated dual assessors without metrics, and eleven reported no reliability data.

Conclusions

There is no standardised and validated method for MPTA measurement after UKA. Heterogeneity in landmarks and reliability reporting undermines the comparability of results across studies. A standardised and validated measurement approach for MPTA after UKA is urgently needed. Level of Evidence Level III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeTibiaOsteoarthritis, KneeKnee JointHumansReproducibility of ResultsKnee Prosthesis

Stichwörter der Autor:innen

Cartier anglecoronal plane alignment classificationmedial proximal tibial angletibial component coronal angleunicompartmental knee arthroplasty

Autor:innen und Institutionen

  • Joint Reconstruction Research Center, Tehran University of Medical Sciences, Tehran, Iran.
  • Department of Orthopaedic Surgery, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran.
  • Nuffield Orthopaedic Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.

ORCID-Profile: Seyed Mohammad Javad Mortazavi

Zitieren

APA

Hajiaghajani, S., Farsani, A. S., Aminizadeh, S., Poursalehian, M., Alvand, A., & Mortazavi, S. M. J. (2026). There is no standardised measurement approach for medial proximal tibial angle after unicompartmental knee arthroplasty: A systematic review. Knee Surgery, Sports Traumatology, Arthroscopy, 34(9), 3322-3332. https://doi.org/10.1002/ksa.70204

Vancouver

Hajiaghajani S, Farsani AS, Aminizadeh S, Poursalehian M, Alvand A, Mortazavi SMJ. There is no standardised measurement approach for medial proximal tibial angle after unicompartmental knee arthroplasty: A systematic review. Knee Surgery, Sports Traumatology, Arthroscopy. 2026;34(9):3322-3332. doi:10.1002/ksa.70204

BibTeX
@article{Hajiaghajani2026,
  author = {Hajiaghajani, Sina and Farsani, Ali Soltani and Aminizadeh, Sina and Poursalehian, Mohammad and Alvand, Abtin and Mortazavi, Seyed Mohammad Javad},
  title = {There is no standardised measurement approach for medial proximal tibial angle after unicompartmental knee arthroplasty: A systematic review},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2026},
  volume = {34},
  number = {9},
  pages = {3322--3332},
  doi = {10.1002/ksa.70204}
}
Kostenlos starten →