Custom‐made total knee arthroplasty with mechanical alignment achieves 94% patient satisfaction at mid‐term follow‐up

Pietro Randelli iD, Valerio Monteleone iD, Paolo Ferrua iD, Alessio Maione iD, Joil Ramazzotti iD, Riccardo Compagnoni iD, Filippo Calanna

Knee Surgery, Sports Traumatology, Arthroscopy · 2025

DOI: 10.1002/ksa.12809 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2025. Verfasst von Pietro Randelli und 6 weiteren Autor:innen. Beteiligte Einrichtung: ASST Centro Specialistico Ortopedico Traumatologico Gaetano Pini-CTO, 1° Clinica Ortopedica, Milan, Italy. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Patient Satisfaction, Prosthesis Design. Die Arbeit nennt 34 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

A notable proportion of patients remain dissatisfied following a total knee arthroplasty (TKA), often due to issues like prosthetic implant overhang, overstuffing, ligament imbalance and paradoxical motion. Custom made implants (CMI) aim to improve this condition by providing patient‐specific solutions tailored to individual knee joint characteristics. The purpose of this prospective study is to evaluate the clinical and radiological outcomes of patients undergoing CMI TKA.

Methods

This prospective study evaluated clinically and radiologically 31 patients (33 knees) undergoing TKA with custom‐made prostheses implanted using mechanical alignment. Pre‐ and post‐operative assessments included patient‐reported outcome measures (PROMs), radiographic evaluations, and analysis of intraoperative and postoperative data. The mean follow‐up period was of 39 ± 22.6 months (range: 9–66 months).

Results

Clinical outcomes, including functional scores and range of motion, showed significant improvements over time. Specifically, at a mean follow‐up of three years after the custom TKA, the Oxford Knee Score (OKS) improved from a preoperative value of 24.3 ± 8.5 to a postoperative value of 41.2 ± 5.9 ( p < 0.01), and the Knee Society Score (KSS) (functional) increased from 54.4 ± 14.2 to 89.8 ± 14.6 ( p < 0.01). Similarly, it was observed an increase in the Forgotten Joint Score (FJS), reaching an average value of 85.8 ± 27.0 (range: 15–100) three years post‐surgery. The radiographic analysis showed an increase in the mechanical Lateral Distal Femoral Angle (mLDFA) from 89.2 ± 4.4 to 90.6 ± 2.5 ( p = 0,03). No significant complications were observed, with the exception of one patient who was diagnosed with aseptic loosening. The overall satisfaction rate was 94%.

Conclusions

CMI demonstrate good clinical and radiological outcomes at mid‐term follow‐up, encouraging further studies to support the potential implementation of this type of implant. Level of Evidence Level II, prospective cohort study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeKnee ProsthesisPatient SatisfactionProsthesis DesignOsteoarthritis, KneeHumansMaleFemaleAgedProspective StudiesFollow-Up StudiesMiddle AgedRange of Motion, ArticularPatient Reported Outcome MeasuresAged, 80 and overKnee JointTreatment Outcome

Stichwörter der Autor:innen

CMIPROMsTKAmechanical alignmentpatient satisfactionpersonalised

Autor:innen und Institutionen

  • ASST Centro Specialistico Ortopedico Traumatologico Gaetano Pini-CTO, 1° Clinica Ortopedica, Milan, Italy.
  • Department of Biomedical Sciences for Health, Laboratory of Applied Biomechanics, Università degli Studi di Milano, Milan, Italy.
  • Department of Biomedical, Surgical and Dental Sciences, Università degli Studi di Milano, Milan, Italy.
  • Department of Biomedical Sciences for Health, Research Center for Adult and Pediatric Rheumatic Diseases (RECAP-RD), Università degli Studi di Milano, Milan, Italy.
  • ASST Bergamo Ovest, Ortopedia e Traumatologia 1, Piazzale Ospedale Luigi Meneguzzo 1, Treviglio, Italy.

ORCID-Profile: Pietro Randelli, Valerio Monteleone, Paolo Ferrua, Alessio Maione, Joil Ramazzotti, Riccardo Compagnoni

Zitieren

APA

Randelli, P., Monteleone, V., Ferrua, P., Maione, A., Ramazzotti, J., Compagnoni, R., & Calanna, F. (2025). Custom‐made total knee arthroplasty with mechanical alignment achieves 94% patient satisfaction at mid‐term follow‐up. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12809

Vancouver

Randelli P, Monteleone V, Ferrua P, Maione A, Ramazzotti J, Compagnoni R, et al. Custom‐made total knee arthroplasty with mechanical alignment achieves 94% patient satisfaction at mid‐term follow‐up. Knee Surgery, Sports Traumatology, Arthroscopy. 2025. doi:10.1002/ksa.12809

BibTeX
@article{Randelli2025,
  author = {Randelli, Pietro and Monteleone, Valerio and Ferrua, Paolo and Maione, Alessio and Ramazzotti, Joil and Compagnoni, Riccardo and Calanna, Filippo},
  title = {Custom‐made total knee arthroplasty with mechanical alignment achieves 94% patient satisfaction at mid‐term follow‐up},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2025},
  doi = {10.1002/ksa.12809}
}