Valgus stress knee radiographs accurately anticipate the bone resection in medial unicompartmental knee arthroplasty: Protocol validation using an image‐based robotic system
Knee Surgery, Sports Traumatology, Arthroscopy · 2025
DOI: 10.1002/ksa.12322 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2025. Verfasst von Stefano Gaggiotti und 7 weiteren Autor:innen. Beteiligte Einrichtung: COT Rafaela - COT Santa Fe, Rafaela, Santa Fe, Argentina. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Tibia, Femur. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: None.
Abstract (Originalsprache)
Purpose
The objective of this study was to describe a planning method for medial unicompartmental knee arthroplasty (UKA) implantation using preoperative stress radiographs to measure the thickness of tibial and femoral bone resections and to validate this method with data from an image‐based robotic surgery system. Having such method for preoperative planning would be of interest for surgeons performing UKA in order to anticipate optimal bone resection on both tibia and femoral sides.
Methods
A new planning method for medial UKA based on valgus stress knee radiographs validated it with an image‐based robotic surgery system (Restoris MCK, MAKO®, Stryker Corporation) was proposed. This retrospective study involved radiographic measurements of 76 patients who underwent image‐based robotic medial UKA between April 2022 and February 2023. Preoperative anteroposterior stress radiographs of the knee were used to simulate UKA implantation. The UKA technique was based on Cartier's angle and aimed at restoring the joint line. The total dimension measured was 14 mm (8 mm for minimal tibial component and polyethylene insert + 4 mm for femoral component + 2 mm for safety laxity). Bone resections were measured in the preoperative valgus stress radiographs and then against the intraoperative bone resection data provided by the robotic system. Inter‐ and intra‐observer reliability was assessed using 25 measurements.
Results
The mean planned tibial resection measured in the radiographs was 4.3 ± 0.4 [2.9–5.8], while the mean robotic resection was 4.2 ± 0.5 [2.7–5.8] (mean difference = 0.15 mm, 95% confidence interval [CI] [–0.27 to 0.57]). There was a strong correlation between these two values (Pearson's rank R = 0.79, p < 0.001). Intra‐ and inter‐observer reliability were also very strong (Pearson's rank R = 0.91, p < 0.001, and Pearson's rank R = 0.82, p < 0.001, respectively). The mean planned femoral bone resection measured in the radiographs was 2.7 ± 0.7 mm [1–4.5], while the mean robotic resection was 2.5 ± 0.9 [1–5] (mean difference = 0.21 mm, 95% CI [−0.66 to 1.08]). There was a strong correlation between these two values (Pearson's rank R = 0.82, p < 0.001). Intra‐ and inter‐observer reliability were also strong (Pearson's rank R = 0.88, p < 0.001, and Pearson's rank R = 0.84, p < 0.001, respectively).
Conclusion
This study describes and validates with robotic information a simple and reproducible preoperative planning method to determine femoral and tibial bone resection for medial UKA implantation using antero‐posterior valgus stress knee radiographs, leaving a medial safety laxity of 2 mm. It represents a very valuable contribution to the understanding of UKA principles, which can serve to extend its indications and increase reproducibility of the surgical technique. Level of Evidence Level III, retrospective cohort study.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- COT Rafaela - COT Santa Fe, Rafaela, Santa Fe, Argentina.
- Sanatorio Mayo, Santa Fe, Argentina.
- Department of Orthopedic Surgery and Sports Medicine, Croix-Rousse Hospital, FIFA Medical Center of Excellence, Lyon, France.
- A.O.U. Azienda Ospedaliera Universitaria Federico II di Napoli, Napoli, Italy.
- EA 7424, Interuniversity Laboratory of Human Movement Science, Université Lyon 1, Lyon, France.
- IFSTTAR, LBMC UMR_T9406, Université de Lyon, Université Claude Bernard Lyon 1, Lyon, France.
Förderung
- None
Zitieren
APA
Gaggiotti, S., Foissey, C., Rossi, V., Batailler, C., Gaggiotti, G., Gaggiotti, S., Servien, E., & Lustig, S. (2025). Valgus stress knee radiographs accurately anticipate the bone resection in medial unicompartmental knee arthroplasty: Protocol validation using an image‐based robotic system. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12322
Vancouver
Gaggiotti S, Foissey C, Rossi V, Batailler C, Gaggiotti G, Gaggiotti S, et al. Valgus stress knee radiographs accurately anticipate the bone resection in medial unicompartmental knee arthroplasty: Protocol validation using an image‐based robotic system. Knee Surgery, Sports Traumatology, Arthroscopy. 2025. doi:10.1002/ksa.12322
BibTeX
@article{Gaggiotti2025,
author = {Gaggiotti, Stefano and Foissey, Constant and Rossi, Valentina and Batailler, Cecile and Gaggiotti, Gabriel and Gaggiotti, Santino and Servien, Elvire and Lustig, Sebastien},
title = {Valgus stress knee radiographs accurately anticipate the bone resection in medial unicompartmental knee arthroplasty: Protocol validation using an image‐based robotic system},
journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
year = {2025},
doi = {10.1002/ksa.12322}
}
EUVIMED