The Size Differences of Breast Cancer and Benign Tumors Measured by Two‐Dimensional Ultrasound and Contrast‐Enhanced Ultrasound
Journal of Ultrasound in Medicine · 2024
DOI: 10.1002/jum.16449 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Ultrasound in Medicine, 2024. Verfasst von Yang Tian und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Nanfang Hospital, Southern Medical University, Guangzhou, China. Hauptthemen laut MEDLINE: Breast Neoplasms, Contrast Media, Ultrasonography, Mammary, Image Enhancement. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 21 Literaturangaben.
Abstract (Originalsprache)
Objectives
Ultrasound (US) imaging has been observed to underestimate tumor size in clinical practice. This study aims to compare the size measurements of breast cancer and benign tumors using two‐dimensional ultrasound (2DUS) and contrast‐enhanced ultrasound (CEUS).
Methods
The study included 42 clinically confirmed breast cancer and 47 benign breast tumors. Two experienced physicians independently measured the maximal longitudinal and transverse diameters of the masses in 2DUS and CEUS. All analyses were performed in R (4.2.2) and GraphPad Prism 6.
Results
The maximal longitudinal and transverse diameters of breast cancer measured by CEUS were 26.61 ± 0.21% and 26.24 ± 0.19% larger compared with 2DUS, and benign breast tumors had an 11.74 ± 0.21% and 11.06 ± 0.14% increase in size compared with 2DUS. The area under the curve (AUC) of the receiver operating characteristic curve (ROC) for the difference between 2DUS and CEUS was 0.870 for longitudinal diameters (95% CI: 0.795–0.945, sensitivity 0.842, specificity 0.783, threshold value 0.215), and 0.863 for transverse diameters (95% CI: 0.785–0.942, sensitivity 0.667, specificity 0.936, threshold value 0.203).
Conclusions
The size measurements of both breast cancer and benign tumors were larger in CEUS compared with 2DUS, with CEUS measurements of breast cancer being more pronounced than those of benign breast tumors. These findings suggest that CEUS may provide a more precise assessment of tumor size, which is crucial for determining optimal treatment strategies and improving patient outcomes in breast cancer management.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Ultrasound, Nanfang Hospital, Southern Medical University, Guangzhou, China.
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, China.
- Department of General Surgery, Southern Theater General Hospital, Guangzhou, China.
- Department of Ultrasound, The 74th Group Military Hospital, Guangzhou, China.
ORCID-Profile: Zheng Liu, Jiawei Tang
Zitieren
APA
Tian, Y., Wang, W., Hu, Y., Chen, F., Liu, Z., Li, L., & Tang, J. (2024). The Size Differences of Breast Cancer and Benign Tumors Measured by Two‐Dimensional Ultrasound and Contrast‐Enhanced Ultrasound. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.16449
Vancouver
Tian Y, Wang W, Hu Y, Chen F, Liu Z, Li L, et al. The Size Differences of Breast Cancer and Benign Tumors Measured by Two‐Dimensional Ultrasound and Contrast‐Enhanced Ultrasound. Journal of Ultrasound in Medicine. 2024. doi:10.1002/jum.16449
BibTeX
@article{Tian2024,
author = {Tian, Yang and Wang, Weizhen and Hu, Yanbin and Chen, Fei and Liu, Zheng and Li, Liangzi and Tang, Jiawei},
title = {The Size Differences of Breast Cancer and Benign Tumors Measured by Two‐Dimensional Ultrasound and Contrast‐Enhanced Ultrasound},
journal = {Journal of Ultrasound in Medicine},
year = {2024},
doi = {10.1002/jum.16449}
}
EUVIMED