The application of contrast-enhanced ultrasound and MicroFlow Imaging in the diagnosis of breast cancer
Journal of Medical Ultrasonics · 2025
DOI: 10.1007/s10396-025-01517-4 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Medical Ultrasonics, 2025. Verfasst von Ting Luo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound Medicine, Taizhou Hospital of Zhejiang Province Affiliated With Wenzhou Medical University, Taizhou, 317000, China. Hauptthemen laut MEDLINE: Breast Neoplasms, Contrast Media, Ultrasonography, Mammary, Ultrasonography, Doppler, Color. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: The purpose of this study was to compare the value of contrast-enhanced ultrasound (CEUS) plus MicroFlow Imaging (CEUS-MFI), MicroFlow Imaging (MFI) alone, and color Doppler flow imaging (CDFI) in the differential diagnosis of benign and malignant breast lesions. METHODS: A total of 116 patients with 116 breast lesions categorized as Breast Imaging Reporting and Data System (BI-RADS) category 4 were enrolled in this prospective study. CEUS-MFI, MFI, and CDFI were used to evaluate the microvascular morphology and distribution types of breast lesions. Pathological results were considered the gold standard. RESULTS: Compared with conventional CDFI and MFI, the CEUS-MFI technique can reveal microvasculature and distribution types at a higher resolution in breast masses. The sensitivity, specificity, and accuracy of CEUS-MFI were 96.3%, 80.6%, and 91.4%, respectively. The sensitivity, specificity, and accuracy of MFI were 87.5%, 75.0%, and 83.6%, respectively. The sensitivity, specificity, and accuracy of CDFI were 58.8%, 72.2%, and 62.9%, respectively. The accuracy was significantly different between CEUS-MFI and MFI (P = 0.024), and the accuracy was significantly different between CEUS-MFI and CDFI (P = 0.000). US BI-RADS 4A masses were downgraded based on CEUS-MFI features without any malignancy missed, with the biopsy rate decreasing from 100% (29/29) to 31.0% (9/29). CONCLUSION: CEUS-MFI provides improved diagnostic efficacy for breast lesions. The CEUS-MFI technique can be used as an effective supplement to conventional ultrasound in the diagnosis of breast tumors.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Ultrasound Medicine, Taizhou Hospital of Zhejiang Province Affiliated With Wenzhou Medical University, Taizhou, 317000, China.
- Department of Ultrasound Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310000, Zhejiang, China.
- Department of Ultrasound Medicine, Taizhou Hospital of Zhejiang Province Affiliated With Wenzhou Medical University, Taizhou, 317000, China. dongjj188@163.com.
Zitieren
APA
Luo, T., Chen, M., He, H., Jiang, T., & Dong, J. (2025). The application of contrast-enhanced ultrasound and MicroFlow Imaging in the diagnosis of breast cancer. Journal of Medical Ultrasonics. https://doi.org/10.1007/s10396-025-01517-4
Vancouver
Luo T, Chen M, He H, Jiang T, Dong J. The application of contrast-enhanced ultrasound and MicroFlow Imaging in the diagnosis of breast cancer. Journal of Medical Ultrasonics. 2025. doi:10.1007/s10396-025-01517-4
BibTeX
@article{Luo2025,
author = {Luo, Ting and Chen, Meizhen and He, Hailing and Jiang, Tianan and Dong, Junjie},
title = {The application of contrast-enhanced ultrasound and MicroFlow Imaging in the diagnosis of breast cancer},
journal = {Journal of Medical Ultrasonics},
year = {2025},
doi = {10.1007/s10396-025-01517-4}
}
EUVIMED