EUVIMEDEUVIMED entdecken
Vergleichsstudie

Value of Contrast-Enhanced Microflow Imaging in Diagnosis of Breast Masses in Comparison with Contrast-Enhanced Ultrasound

Runlan Luo, Qingyao Wang, Yan Zhang, Wenli Jiang, Yiru Wang, Yukun Luo

Academic Radiology · 2024-06 · 31 (6) · 2217-2227

DOI: 10.1016/j.acra.2023.11.021 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Academic Radiology, 2024-06. Verfasst von Runlan Luo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Medical College, Yangzhou University, No. 136 Jiangyang Middle Rd, Hanjiang District, Yangzhou, Jiangsu, China (R.L.); Department of Ultrasound, Divi…. Hauptthemen laut MEDLINE: Breast Neoplasms, Contrast Media, Ultrasonography, Mammary. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES: To investigate the value of contrast-enhanced microflow imaging (CEUS-MFI) in distinguishing benign and malignant breast masses. METHODS: A total of 116 breast masses classified as Breast Imaging Reporting and Data System (BI-RADS) category 3-5 by ultrasound (US) were included. Both contrast-enhanced ultrasound (CEUS) and CEUS-MFI were performed before excision or biopsy, with features and diagnostic efficiency analyzed. The US and CEUS BI-RADS 4A masses were also re-assessed by CEUS-MFI. RESULTS: The features of CEUS-MFI including both interior and peripheral enlarged, twisted vessels (both P < 0.05), penetrating vessels (P = 0.007), and radial/spiculated vessels (P < 0.001) were more frequently detected in malignant masses, while peripheral annular vessels were mostly observed in benign masses (P < 0.001). Interestingly, a significant difference in the orientation of penetrating vessels between benign and malignant masses was found (P < 0.001), with parallel orientation mostly displayed in benign masses, while vertical or multiple-direction orientation mostly displayed in malignant masses. The microvascular architecture of breast masses was categorized into five patterns: avascular, line-like, tree-like, root hair-like, and crab claw-like pattern. Benign masses mainly displayed tree-like pattern (77.1% vs 10.9%, P < 0.05); malignant masses mainly displayed root hair-like (34.8% vs 5.7%, P < 0.05) and crab claw-like patterns (50.0% vs 1.4%, P < 0.05). The diagnostic efficiency of CEUS-MFI was higher relative to CEUS and US. In addition, CEUS-MFI decreased the biopsy rates of US and CEUS BI-RADS 4A masses without missing malignancies. CONCLUSION: CEUS-MFI could be a valuable and promising technique in diagnosis of breast masses, and could provide more diagnostic information for radiologists.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breast NeoplasmsContrast MediaUltrasonography, MammaryHumansFemaleMiddle AgedAdultAgedDiagnosis, DifferentialImage EnhancementSensitivity and SpecificityYoung AdultBreastMicrovessels

Stichwörter der Autor:innen

Breast neoplasmsContrast mediaDiagnostic imagingMammary ultrasonographyMicrovessels

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Medical College, Yangzhou University, No. 136 Jiangyang Middle Rd, Hanjiang District, Yangzhou, Jiangsu, China (R.L.); Department of Ultrasound, Division of First Medical Center, Chinese People's Liberation Army General…
  • Department of Ultrasound, Division of First Medical Center, Chinese People's Liberation Army General Hospital, No. 28 Fuxing Rd, Haidian District, Beijing, China (R.L., Q.W., Y.Z., W.J., Y.W., Y.L.).
  • Department of Ultrasound, Division of First Medical Center, Chinese People's Liberation Army General Hospital, No. 28 Fuxing Rd, Haidian District, Beijing, China (R.L., Q.W., Y.Z., W.J., Y.W., Y.L.). Electronic address:…

Zitieren

APA

Luo, R., Wang, Q., Zhang, Y., Jiang, W., Wang, Y., & Luo, Y. (2024). Value of Contrast-Enhanced Microflow Imaging in Diagnosis of Breast Masses in Comparison with Contrast-Enhanced Ultrasound. Academic Radiology, 31(6), 2217-2227. https://doi.org/10.1016/j.acra.2023.11.021

Vancouver

Luo R, Wang Q, Zhang Y, Jiang W, Wang Y, Luo Y. Value of Contrast-Enhanced Microflow Imaging in Diagnosis of Breast Masses in Comparison with Contrast-Enhanced Ultrasound. Academic Radiology. 2024;31(6):2217-2227. doi:10.1016/j.acra.2023.11.021

BibTeX
@article{Luo2024,
  author = {Luo, Runlan and Wang, Qingyao and Zhang, Yan and Jiang, Wenli and Wang, Yiru and Luo, Yukun},
  title = {Value of Contrast-Enhanced Microflow Imaging in Diagnosis of Breast Masses in Comparison with Contrast-Enhanced Ultrasound},
  journal = {Academic Radiology},
  year = {2024},
  volume = {31},
  number = {6},
  pages = {2217--2227},
  doi = {10.1016/j.acra.2023.11.021}
}
Kostenlos starten →