EUVIMEDEUVIMED entdecken
Crossref

Temperature Monitoring During Microwave Hyperthermia Based on BP‐Nakagami Distribution

Zhengkai Liu iD, Yongxing Du, Xainwei Meng, Chenlu Li, Liyong Zhou

Journal of Ultrasound in Medicine · 2023

DOI: 10.1002/jum.16213 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Ultrasound in Medicine, 2023. Verfasst von Zhengkai Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Inner Mongolia University of Science & Technology, Baotou, China. Hauptthemen laut MEDLINE: Microwaves, Hyperthermia, Induced. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Major Science and Technology Project of Inner Mongolia Autonomous Region, National Natural Science Foundation of China, Natural Science Foundation of Inner Mongolia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The purpose of this study is to accurately monitor temperature during microwave hyperthermia. We propose a temperature estimation model BP‐Nakagami based on neural network for Nakagami distribution.

Methods

In this work, we designed the microwave hyperthermia experiment of fresh ex vivo pork tissue and phantom, collected ultrasonic backscatter data at different temperatures, modeled these data using Nakagami distribution, and calculated Nakagami distribution parameter m . A neural network model was built to train the relationship between Nakagami distribution parameter m and temperature, and a BP‐Nakagami temperature model with good fitting was obtained. The temperature model is used to draw the two‐dimensional temperature distribution map of biological tissues in microwave hyperthermia. Finally, the temperature estimated by the model is compared with the temperature measured by thermocouples.

Results

The error between the temperature estimated by the temperature model and the temperature measured by the thermocouple is within 1°C in the range of 25°C–50°C for ex vivo pork tissue, and the error between the temperature estimated by the temperature model and the temperature measured by the thermocouple is within 0.5°C in the range of 25°C–50°C for phantom.

Conclusions

The results show that the temperature estimation model proposed by us is an effective model for monitoring the internal temperature change of biological tissues.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicrowavesHyperthermia, InducedHumansTemperatureUltrasonicsPhantoms, ImagingUltrasonography

Stichwörter der Autor:innen

Nakagami distributionmicrowave ablationneural networkultrasonic noninvasive temperature monitoring

Autor:innen und Institutionen

  • Inner Mongolia University of Science & Technology, Baotou, China.
  • Technical Institute of Physics and Chemistry CAS, Beijing, China.

ORCID-Profile: Zhengkai Liu

Förderung

  • Major Science and Technology Project of Inner Mongolia Autonomous Region
  • National Natural Science Foundation of China
  • Natural Science Foundation of Inner Mongolia
  • Research and Practice Project of postgraduate education and teaching reform in Inner Mongolia Autonomous Region

Zitieren

APA

Liu, Z., Du, Y., Meng, X., Li, C., & Zhou, L. (2023). Temperature Monitoring During Microwave Hyperthermia Based on BP‐Nakagami Distribution. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.16213

Vancouver

Liu Z, Du Y, Meng X, Li C, Zhou L. Temperature Monitoring During Microwave Hyperthermia Based on BP‐Nakagami Distribution. Journal of Ultrasound in Medicine. 2023. doi:10.1002/jum.16213

BibTeX
@article{Liu2023,
  author = {Liu, Zhengkai and Du, Yongxing and Meng, Xainwei and Li, Chenlu and Zhou, Liyong},
  title = {Temperature Monitoring During Microwave Hyperthermia Based on BP‐Nakagami Distribution},
  journal = {Journal of Ultrasound in Medicine},
  year = {2023},
  doi = {10.1002/jum.16213}
}
Kostenlos starten →