Ultrasound Homodyned-K Contrast-Weighted Summation Parametric Imaging Based on H-scan for Detecting Microwave Ablation Zones
Ultrasonic Imaging · 2023
DOI: 10.1177/01617346231162928 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ultrasonic Imaging, 2023. Verfasst von Sinan Li und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, China. Hauptthemen laut MEDLINE: Microwaves, Liver. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 68 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Beijing Municipality.
Abstract (Originalsprache)
The homodyned-K (HK) distribution is a generalized model of envelope statistics whose parameters α (the clustering parameter) and k (the coherent-to-diffuse signal ratio) can be used to monitor the thermal lesions. In this study, we proposed an ultrasound HK contrast-weighted summation (CWS) parametric imaging algorithm based on the H-scan technique and investigated the optimal window side length (WSL) of the HK parameters estimated by the XU estimator (an estimation method based on the first moment of the intensity and two log-moments, which was used in the proposed algorithm) through phantom simulations. H-scan diversified ultrasonic backscattered signals into low- and high-frequency passbands. After envelope detection and HK parameter estimation for each frequency band, the α and k parametric maps were obtained, respectively. According to the contrast between the target region and background, the ( α or k) parametric maps of the dual-frequency band were weighted and summed, and then the CWS images were yielded by pseudo-color imaging. The proposed HK CWS parametric imaging algorithm was used to detect the microwave ablation coagulation zones of porcine liver ex vivo under different powers and treatment durations. The performance of the proposed algorithm was compared with that of the conventional HK parametric imaging and frequency diversity and compounding Nakagami imaging algorithms. For two-dimensional HK parametric imaging, it was found that a WSL equal to 4 pulse lengths of the transducer was sufficient for estimating the α and k parameters in terms of both parameter estimation stability and parametric imaging resolution. The HK CWS parametric imaging provided an improved contrast-to-noise ratio over conventional HK parametric imaging, and the HK α cws parametric imaging achieved the best accuracy and Dice score of coagulation zone detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, China.
- College of Biomedical Engineering, Capital Medical University, Beijing, China.
ORCID-Profile: Sinan Li, Zhuhuang Zhou
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Beijing Municipality
Zitieren
APA
Li, S., Zhou, Z., Wu, S., & Wu, W. (2023). Ultrasound Homodyned-K Contrast-Weighted Summation Parametric Imaging Based on H-scan for Detecting Microwave Ablation Zones. Ultrasonic Imaging. https://doi.org/10.1177/01617346231162928
Vancouver
Li S, Zhou Z, Wu S, Wu W. Ultrasound Homodyned-K Contrast-Weighted Summation Parametric Imaging Based on H-scan for Detecting Microwave Ablation Zones. Ultrasonic Imaging. 2023. doi:10.1177/01617346231162928
BibTeX
@article{Li2023,
author = {Li, Sinan and Zhou, Zhuhuang and Wu, Shuicai and Wu, Weiwei},
title = {Ultrasound Homodyned-K Contrast-Weighted Summation Parametric Imaging Based on H-scan for Detecting Microwave Ablation Zones},
journal = {Ultrasonic Imaging},
year = {2023},
doi = {10.1177/01617346231162928}
}
EUVIMED