3.0T magnetic resonance imaging‐based hip bone models for femoroacetabular impingement syndrome are equivalent to computed tomography‐based models
Journal of Orthopaedic Research · 2024
DOI: 10.1002/jor.25845 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Orthopaedic Research, 2024. Verfasst von Alexander C Newhouse und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Femoracetabular Impingement, Tomography, X-Ray Computed. Die Arbeit nennt 24 Literaturangaben. Gefördert von: Michael And Jaqueline Newman Orthopaedic Research Fund, Stryker Corp.
Abstract (Originalsprache)
This study aimed to compare three‐dimensional (3D) proximal femoral and acetabular surface models generated from 3.0T magnetic resonance imaging (MRI) to the clinical gold standard of computed tomography (CT). Ten intact fresh‐frozen cadaveric hips underwent CT and 3.0T MRI scans. The CT‐ and MRI‐based segmented models were superimposed using a validated 3D–3D registration volume‐merge method to compare them. The least surface‐to‐surface distance between the models was calculated by a point‐to‐surface calculation algorithm using a custom‐written program. The variables of interest were the signed and absolute surface‐to‐surface distance between the paired bone models. One‐sample t ‐tests were performed using a signed and absolute test value of 0.16 mm and 0.37 mm, respectively, based on a previous study that validated 1.5T MRI bone models by comparison with CT bone models. For the femur, the average signed and absolute surface‐to‐surface distance was 0.18 ± 0.09 mm and 0.30 ± 0.06 mm, respectively. There was no difference in the signed surface‐to‐surface distance and the 0.16 mm test value ( t = 0.650, p = 0.532). However, the absolute surface‐to‐surface difference was less than the 0.37 mm test value (t = −4.025, p = 0.003). For the acetabulum, the average signed and absolute surface‐to‐surface distance was −0.06 ± 0.06 mm and 0.26 ± 0.04 mm, respectively. The signed (t = −12.569, p < 0.001) and absolute ( t = −8.688, p < 0.001) surface‐to‐surface difference were less than the 0.16 mm and 0.37 mm test values, respectively. Our data shows that 3.0T MRI bone models are more similar to CT bone models than previously validated 1.5T MRI bone models. This is likely due to the higher resolution of the 3T data.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA.
- Department of Bioengineering, University of Illinois Chicago, Chicago, Illinois, USA.
ORCID-Profile: Alejandro A Espinoza Orías
Förderung
- Michael And Jaqueline Newman Orthopaedic Research Fund
- Stryker Corp
Zitieren
APA
Newhouse, A. C., Alter, T. D., Handoklow, L. A., Espinoza Orías, A. A., Inoue, N., & Nho, S. J. (2024). 3.0T magnetic resonance imaging‐based hip bone models for femoroacetabular impingement syndrome are equivalent to computed tomography‐based models. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.25845
Vancouver
Newhouse AC, Alter TD, Handoklow LA, Espinoza Orías AA, Inoue N, Nho SJ. 3.0T magnetic resonance imaging‐based hip bone models for femoroacetabular impingement syndrome are equivalent to computed tomography‐based models. Journal of Orthopaedic Research. 2024. doi:10.1002/jor.25845
BibTeX
@article{Newhouse2024,
author = {Newhouse, Alexander C and Alter, Thomas D and Handoklow, Lyla A and Espinoza Orías, Alejandro A and Inoue, Nozomu and Nho, Shane J},
title = {3.0T magnetic resonance imaging‐based hip bone models for femoroacetabular impingement syndrome are equivalent to computed tomography‐based models},
journal = {Journal of Orthopaedic Research},
year = {2024},
doi = {10.1002/jor.25845}
}
EUVIMED