Discrepancies in Magnetic Resonance– and Computed Tomography–Based Femoral Version Measurements Despite Strong Correlations

Siqi Zhang, Ke Liu, Guanying Gao, Ning Lang, Yan Xu

Arthroscopy · 2024

DOI: 10.1016/j.arthro.2023.12.025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Arthroscopy, 2024. Verfasst von Siqi Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sports Medicine, Institute of Sports Medicine of Peking University, Peking University Third Hospital, Beijing, China; Beijing Key Labor…. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Magnetic Resonance Imaging, Femur, Femoracetabular Impingement. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: Natural Science Foundation of Beijing Municipality, Beijing Municipal Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To determine the correlation and classification consistency of femoral version measurements between magnetic resonance (MR) and computed tomography (CT) using 4 commonly used measurement methods.

Methods

A retrospective study was performed on patients with femoroacetabular impingement (FAI) who received preoperative CT and MR imaging assessment of the surgical hip and ipsilateral distal femur. Femoral version was measured using the Murphy method, the oblique method, the Reikerås method, and the Lee method. Intra‐ and inter‐rater agreements were calculated. Linear regression and Bland‐Altman analysis were performed for measurements using different imaging modalities and measurement methods. Femoral version measurements within the lower quartile, the middle 2 quartiles, and the upper quartile were classified into different groups based on their percentile within the sample population. Classification consistency rates between modalities and methods were calculated and compared.

Results

Fifty‐three patients (39.4 ± 9.1 years; 32 female) were included for analysis. Intra‐ and inter‐rater reliability were high for all modalities and methods (intrarater intraclass correlation coefficient [ICC] range, 0.963‐0.993; inter‐rater ICC range, 0.871‐0.960). MR‐ and CT‐based femoral version measurements showed strong correlations for all methods, with the Lee method demonstrating the strongest association ( r = 0.904), while the oblique method exhibited the lowest correlation ( r = 0.684) (all P < .001). MR‐based measurements were smaller than CT‐based measurements, with mean differences ranging from 4.5° to 10.3°. Classification consistency between MR and CT ranged from 51% to 74%, whereas the consistency between different measurement methods ranged from 68% to 85%.

Conclusions

While strong correlations were observed between MR‐ and CT‐based femoral version measurements, MR‐based measurements were significantly smaller than their CT counterparts. Classification consistency between the modalities was moderate to high. Measurements between different methods showed strong correlations with high consistency rates. Level of Evidence Level III, retrospective case series.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedMagnetic Resonance ImagingFemurFemoracetabular ImpingementHumansFemaleMaleRetrospective StudiesAdultMiddle AgedReproducibility of Results

Autor:innen und Institutionen

  • Department of Sports Medicine, Institute of Sports Medicine of Peking University, Peking University Third Hospital, Beijing, China; Beijing Key Laboratory of Sports Injuries, Beijing, China; Engineering Research Center…
  • Department of Radiology, Peking University Third Hospital, Beijing, China.

Förderung

  • Natural Science Foundation of Beijing Municipality
  • Beijing Municipal Natural Science Foundation

Zitieren

APA

Zhang, S., Liu, K., Gao, G., Lang, N., & Xu, Y. (2024). Discrepancies in Magnetic Resonance– and Computed Tomography–Based Femoral Version Measurements Despite Strong Correlations. Arthroscopy. https://doi.org/10.1016/j.arthro.2023.12.025

Vancouver

Zhang S, Liu K, Gao G, Lang N, Xu Y. Discrepancies in Magnetic Resonance– and Computed Tomography–Based Femoral Version Measurements Despite Strong Correlations. Arthroscopy. 2024. doi:10.1016/j.arthro.2023.12.025

BibTeX
@article{Zhang2024,
  author = {Zhang, Siqi and Liu, Ke and Gao, Guanying and Lang, Ning and Xu, Yan},
  title = {Discrepancies in Magnetic Resonance– and Computed Tomography–Based Femoral Version Measurements Despite Strong Correlations},
  journal = {Arthroscopy},
  year = {2024},
  doi = {10.1016/j.arthro.2023.12.025}
}
Kostenlos starten →