Comparison of Retrospective Motion Compensation Techniques for Pulmonary Dynamic Ultrashort Time to Echo MRI in Suspected Idiopathic Pulmonary Fibrosis
Journal of Magnetic Resonance Imaging · 2026-09 · 64 (3) · 644-654
DOI: 10.1002/jmri.70350 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Magnetic Resonance Imaging, online erschienen am 23.05.2026. Verfasst von Abhilash S Kizhakke Puliyakote und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Iowa HealthCare, Iowa City, Iowa, USA. Hauptthemen laut MEDLINE: Idiopathic Pulmonary Fibrosis, Magnetic Resonance Imaging, Lung, Image Processing, Computer-Assisted. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS, NIH HHS, NCATS NIH HHS.
Abstract (Originalsprache)
Background
Motion can degrade image quality during Ultrashort Time‐to‐Echo (UTE) pulmonary MRI and is particularly prevalent in patients with lung disease. Comprehensive assessment of the impact of motion compensation techniques on image quality and clinical interpretation is needed. Purpose/Hypothesis To compare the impact of retrospective motion compensation schemes on image quality and clinical interpretation of pulmonary UTE MRI in idiopathic pulmonary fibrosis (IPF). Study Type Prospective. Population 21 (male = 18; mean age, 69.9 ± 8.1 years) participants with suspected IPF. Field Strength/Sequence 1.5 T/3 T, 3D center‐out radial (gradient‐echo) UTE sequence with 2× radial oversampling, while free‐breathing. Assessment Images were reconstructed to 1.25 mm isotropic resolution using five retrospective schemes: no gating, hard‐gating, soft‐gating, motion‐resolved (XD‐GRASP), and an iterative approach (iMoCo). Signal‐to‐noise ratios (SNR) were estimated within the lung parenchyma, airways, aorta, muscles, and liver. Contrast‐to‐noise ratios (CNR) were estimated using the mean airway signal as reference. Image sharpness was estimated using the maximum derivative of a line profile across the diaphragm and a wavelet‐based autofocus measure. Three radiologists evaluated image quality, motion artifacts on a 5‐point Likert scale, and diagnostic classification of usual interstitial pneumonia (UIP). Statistical Tests The Kruskal–Wallis non‐parametric test was used for qualitative reader scores and one‐way ANOVA for the quantitative metrics, with p < 0.05 as the threshold for significance.
Results
CNR was highest using the iMoCo reconstructions (lung parenchyma: 1.64 ± 1.41 vs. 0.88 ± 0.81 via XD‐GRASP). Image sharpness was significantly improved using compressed sensing (CS)‐based techniques (XD‐GRASP and iMoCo), compared to the other methods, using both diaphragm profile (CS: 6.28 ± 3.70 vs. non‐CS: 3.73 ± 2.06) and wavelet metrics (CS: 2.33 ± 0.42 vs. non‐CS: 2.05 ± 0.35). CS methods also demonstrated greatest image quality based on reader scores.
Conclusion
Motion compensation using compressed sensing methods can improve image quality and clinical utility of UTE‐MRI in the identification and diagnostic classification of typical parenchymal fibrotic patterns. Evidence Level Level 2—Prospective study, with a reference standard determined during the course of the study (CT imaging). Technical Efficacy Stage 1.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, University of Iowa HealthCare, Iowa City, Iowa, USA.
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Roy J. Carver Department of Biomedical Engineering, University of Iowa, Iowa City, Iowa, USA.
- Department of Radiology, Duke University School of Medicine, Durham, North Carolina, USA.
ORCID-Profile: Abhilash S Kizhakke Puliyakote, Luis A Torres, Kevin M Johnson, Bryan O'Sullivan-Murphy, Andrew D Hahn, Sean B Fain
Förderung
- NHLBI NIH HHS
- NIH HHS
- NCATS NIH HHS
- NIH/NCATS
- National Institutes of Health
- National Heart, Lung, and Blood Institute
- National Center for Advancing Translational Sciences
Zitieren
APA
Kizhakke Puliyakote, A. S., Torres, L. A., AlAtoum, A., AlArab, N., Johnson, K. M., Bello, R. M., O'Sullivan-Murphy, B., Mammarappallil, J. G., Hahn, A. D., & Fain, S. B. (2026). Comparison of Retrospective Motion Compensation Techniques for Pulmonary Dynamic Ultrashort Time to Echo MRI in Suspected Idiopathic Pulmonary Fibrosis. Journal of Magnetic Resonance Imaging, 64(3), 644-654. https://doi.org/10.1002/jmri.70350
Vancouver
Kizhakke Puliyakote AS, Torres LA, AlAtoum A, AlArab N, Johnson KM, Bello RM, et al. Comparison of Retrospective Motion Compensation Techniques for Pulmonary Dynamic Ultrashort Time to Echo MRI in Suspected Idiopathic Pulmonary Fibrosis. Journal of Magnetic Resonance Imaging. 2026;64(3):644-654. doi:10.1002/jmri.70350
BibTeX
@article{KizhakkePuliyakote2026,
author = {Kizhakke Puliyakote, Abhilash S and Torres, Luis A and AlAtoum, Aiah and AlArab, Natally and Johnson, Kevin M and Bello, Rodrigo M and O'Sullivan-Murphy, Bryan and Mammarappallil, Joseph G and Hahn, Andrew D and Fain, Sean B},
title = {Comparison of Retrospective Motion Compensation Techniques for Pulmonary Dynamic Ultrashort Time to Echo MRI in Suspected Idiopathic Pulmonary Fibrosis},
journal = {Journal of Magnetic Resonance Imaging},
year = {2026},
volume = {64},
number = {3},
pages = {644--654},
doi = {10.1002/jmri.70350}
}
EUVIMED