EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cardiac MR Fingerprinting at 0.55T Using a Deep Image Prior for Joint T 1 , T 2 , and M 0 Mapping

Zhongnan Liu iD, Zexuan Liu, Imran Rashid, Mauricio Stanzione Galizia, Christopher Scoma, William Truesdell, Prachi Agarwal, Nicole Seiberlich, Liyue Shen, Jesse Hamilton iD

Journal of Magnetic Resonance Imaging · 2026

DOI: 10.1002/jmri.70239 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2026. Verfasst von Zhongnan Liu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan, USA. Hauptthemen laut MEDLINE: Heart, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Siemens Healthineers, NHI, MICDE Catalyst Grant.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

0.55T systems offer unique advantages and may support expanded access to cardiac MRI.

Purpose

To assess the feasibility of 0.55T cardiac MR Fingerprinting (MRF), leveraging a deep image prior reconstruction to mitigate noise. Study Type Phantom and prospective in vivo assessment. Population ISMRM/NIST MRI system phantom and 18 healthy subjects (11 female; ages 28 ± 8 years). Field Strength and Sequences MRF, modified Look‐Locker inversion recovery (MOLLI), and T 2 ‐prepared balanced steady state free precession (T 2 ‐bSSFP) at 0.55T. Assessment MRF T 1 and T 2 maps were reconstructed using (1) a low‐rank technique with sparse and locally low‐rank regularization (SLLR‐MRF) and (2) a deep image prior (DIP‐MRF). Accuracy and precision of MRF and conventional sequences were evaluated in a phantom. In vivo performance of MRF was evaluated in the 18 healthy subjects, with 7 subjects also undergoing conventional mapping. Myocardial T 1 and T 2 values were compared among methods and image quality scored by three readers (2, 3, and 4 years of experience) on a 5‐point scale. Statistical Tests Linear regression, Bland–Altman, intraclass correlation coefficient, and one‐way ANOVA with p < 0.05 considered significant.

Results

Mean measurements in the left ventricular septum were 671 ± 31 ms (MOLLI), 761 ± 147 ms (SLLR‐MRF), and 686 ± 39 ms (DIP‐MRF) for T 1 , and 63.5 ± 5.7 ms (T 2 ‐bSSFP), 47.5 ± 12.7 ms (SLLR‐MRF), and 45.2 ± 4.5 ms (DIP‐MRF) for T 2 . Compared to conventional mapping, DIP‐MRF exhibited significantly lower T 2 but no differences in T 1 ( p > 0.99). Standard deviations within the myocardium were significantly lower with DIP‐MRF compared to SLLR‐MRF (39 vs. 147 ms for T 1 and 4.5 vs. 12.7 ms for T 2 ). Overall image quality ratings were significantly lower for SLLR‐MRF (T 1 : 2.3, T 2 : 2.9), which were significantly lower compared to conventional mapping methods (T 1 : 3.4, T 2 : 3.9), and DIP‐MRF (T 1 : 3.8, T 2 : 4.1) received higher scores. Data Conclusion This study demonstrated the feasibility of cardiac MRF on a commercial 0.55T system, enabled by a deep image prior reconstruction for denoising. Evidence Level 2. Stage of Technical Efficacy 1.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HeartMagnetic Resonance ImagingImage Processing, Computer-AssistedHumansFemalePhantoms, ImagingAdultMaleProspective StudiesFeasibility StudiesAlgorithmsReproducibility of ResultsYoung AdultImage Interpretation, Computer-AssistedHealthy Volunteers

Stichwörter der Autor:innen

MR fingerprintingT1 mappingT2 mappingcardiacdeep learninglow field

Autor:innen und Institutionen

  • Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan, USA.
  • Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
  • School of Medicine, Case Western Reserve University, Cleveland, Ohio, USA.
  • Harrington Heart and Vascular Institute, University Hospitals, Cleveland, Ohio, USA.
  • Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA.
  • Division of Cardiovascular Medicine, University of Michigan, Ann Arbor, Michigan, USA.

ORCID-Profile: Zhongnan Liu, Jesse Hamilton

Förderung

  • Siemens Healthineers
  • NHI
  • MICDE Catalyst Grant
  • NSF
  • DARPA
  • MIDAS PODS
  • Defense Advanced Research Projects Agency
  • National Heart, Lung, and Blood Institute

Zitieren

APA

Liu, Z., Liu, Z., Rashid, I., Galizia, M. S., Scoma, C., Truesdell, W., Agarwal, P., Seiberlich, N., Shen, L., & Hamilton, J. (2026). Cardiac MR Fingerprinting at 0.55T Using a Deep Image Prior for Joint T 1 , T 2 , and M 0 Mapping. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.70239

Vancouver

Liu Z, Liu Z, Rashid I, Galizia MS, Scoma C, Truesdell W, et al. Cardiac MR Fingerprinting at 0.55T Using a Deep Image Prior for Joint T 1 , T 2 , and M 0 Mapping. Journal of Magnetic Resonance Imaging. 2026. doi:10.1002/jmri.70239

BibTeX
@article{Liu2026,
  author = {Liu, Zhongnan and Liu, Zexuan and Rashid, Imran and Galizia, Mauricio Stanzione and Scoma, Christopher and Truesdell, William and Agarwal, Prachi and Seiberlich, Nicole and Shen, Liyue and Hamilton, Jesse},
  title = {Cardiac MR Fingerprinting at 0.55T Using a Deep Image Prior for Joint T 1 , T 2 , and M 0 Mapping},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2026},
  doi = {10.1002/jmri.70239}
}
Kostenlos starten →