Reproducibility of Quantitative Double‐Echo Steady‐State T 2 Mapping of Knee Cartilage
Journal of Magnetic Resonance Imaging · 2025-02 · 61 (2) · 784-795
DOI: 10.1002/jmri.29431 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, online erschienen am 04.05.2024. Verfasst von Ashley A Williams und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Stanford University, Stanford, California, USA. Hauptthemen laut MEDLINE: Cartilage, Articular, Magnetic Resonance Imaging, Knee Joint. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: U.S. Department of Defense, NIBIB NIH HHS, NIAMS NIH HHS.
Abstract (Originalsprache)
Background
Cartilage T 2 can detect joints at risk of developing osteoarthritis. The quantitative double‐echo steady state (qDESS) sequence is attractive for knee cartilage T 2 mapping because of its acquisition time of under 5 minutes. Understanding the reproducibility errors associated with qDESS T 2 is essential to profiling the technical performance of this biomarker.
Purpose
To examine the combined acquisition and segmentation reproducibility of knee cartilage qDESS T 2 using two different regional analysis schemes: 1) manual segmentation of subregions loaded during common activities and 2) automatic subregional segmentation. Study Type Prospective. Subjects 11 uninjured participants (age: 28 ± 3 years; 8 (73%) female). Field Strength/Sequence 3‐T, qDESS. Assessment Test–retest T 2 maps were acquired twice on the same day and with a 1‐week interval between scans. For each acquisition, average cartilage T 2 was calculated in four manually segmented regions encompassing tibiofemoral contact areas during common activities and 12 automatically segmented regions from the deep‐learning open‐source framework for musculoskeletal MRI analysis (DOSMA) encompassing medial and lateral anterior, central, and posterior tibiofemoral regions. Test–retest T 2 values from matching regions were used to evaluate reproducibility. Statistical Tests Coefficients of variation (%CV), root‐mean‐square‐average‐CV (%RMSA‐CV), and intraclass correlation coefficients (ICCs) assessed test–retest T 2 reproducibility. The median of test–retest standard deviations was used for T 2 precision. Bland–Altman (BA) analyses examined test–retest biases. The smallest detectable difference (SDD) was defined as the BA limit of agreement of largest magnitude. Significance was accepted for P < 0.05.
Results
All cartilage regions across both segmentation schemes demonstrated intraday and interday qDESS T 2 CVs and RMSA‐CVs of ≤5%. T 2 ICC values >0.75 were observed in the majority of regions but were more variable in interday tibial comparisons. Test–retest T 2 precision was 5% (3.8 msec) could represent changes to cartilage composition. Level of Evidence 2. Technical Efficacy Stage 2.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Stanford University, Stanford, California, USA.
- VA Palo Alto Health Care System, Palo Alto, California, USA.
- Department of Radiology, Stanford University, Stanford, California, USA.
- Department of Electrical Engineering, Stanford University, Stanford, California, USA.
- Department of Bioengineering, Stanford University, Stanford, California, USA.
- Department of Biomedical Data Science, Stanford University, Stanford, California, USA.
ORCID-Profile: Ashley A Williams, Garry E Gold, Akshay S Chaudhari
Förderung
- U.S. Department of Defense
- NIBIB NIH HHS
- NIAMS NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Williams, A. A., Asay, J. L., Asare, D., Desai, A. D., Gold, G. E., Hargreaves, B. A., Chaudhari, A. S., & Chu, C. R. (2025). Reproducibility of Quantitative Double‐Echo Steady‐State T 2 Mapping of Knee Cartilage. Journal of Magnetic Resonance Imaging, 61(2), 784-795. https://doi.org/10.1002/jmri.29431
Vancouver
Williams AA, Asay JL, Asare D, Desai AD, Gold GE, Hargreaves BA, et al. Reproducibility of Quantitative Double‐Echo Steady‐State T 2 Mapping of Knee Cartilage. Journal of Magnetic Resonance Imaging. 2025;61(2):784-795. doi:10.1002/jmri.29431
BibTeX
@article{Williams2025,
author = {Williams, Ashley A and Asay, Jessica L and Asare, Daniella and Desai, Arjun D and Gold, Garry E and Hargreaves, Brian A and Chaudhari, Akshay S and Chu, Constance R},
title = {Reproducibility of Quantitative Double‐Echo Steady‐State T 2 Mapping of Knee Cartilage},
journal = {Journal of Magnetic Resonance Imaging},
year = {2025},
volume = {61},
number = {2},
pages = {784--795},
doi = {10.1002/jmri.29431}
}
EUVIMED