Repeatability of Quantitative Knee Cartilage T 1 , T 2 , and T 1ρ Mapping With 3D‐MRI Fingerprinting
Journal of Magnetic Resonance Imaging · 2024
DOI: 10.1002/jmri.29068 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2024. Verfasst von Xiaoxia Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Center of Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Magnetic Resonance Imaging, Cartilage, Articular, Knee Joint. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NIAMS NIH HHS, NIBIB NIH HHS.
Abstract (Originalsprache)
Background
Three‐dimensional MR fingerprinting (3D‐MRF) techniques have been recently described for simultaneous multiparametric mapping of knee cartilage. However, investigation of repeatability remains limited.
Purpose
To assess the intra‐day and inter‐day repeatabilities of knee cartilage T 1 , T 2 , and T 1ρ maps using a 3D‐MRF sequence for simultaneous measurement. Study Type Prospective. Subjects Fourteen healthy subjects (35.4 ± 9.3 years, eight males), scanned on Day 1 and Day 7. Field Strength/Sequence 3 T/3D‐MRF, T 1 , T 2 , and T 1ρ maps. Assessment The acquisition of 3D‐MRF cartilage (simultaneous acquisition of T 1 , T 2 , and T 1ρ maps) were acquired using a dictionary pattern‐matching approach. Conventional cartilage T 1 , T 2 , and T 1ρ maps were acquired using variable flip angles and a modified 3D‐Turbo‐Flash sequence with different echo and spin‐lock times, respectively, and were fitted using mono‐exponential models. Each sequence was acquired on Day 1 and Day 7 with two scans on each day. Statistical Tests The mean and SD for cartilage T 1 , T 2 , and T 1ρ were calculated in five manually segmented regions of interest (ROIs), including lateral femur, lateral tibia, medial femur, medial tibia, and patella cartilages. Intra‐subject and inter‐subject repeatabilities were assessed using coefficient of variation (CV) and intra‐class correlation coefficient (ICC), respectively, on the same day and among different days. Regression and Bland–Altman analysis were performed to compare maps between the conventional and 3D‐MRF sequences.
Results
The CV in all ROIs was lower than 7.4%, 8.4%, and 7.5% and the ICC was higher than 0.56, 0.51, and 0.52 for cartilage T 1 , T 2 , and T 1ρ , respectively. The MRF results had a good agreement with the conventional methods with a linear regression slope >0.61 and R 2 > 0.59.
Conclusion
The 3D‐MRF sequence had high intra‐subject and inter‐subject repeatabilities for simultaneously measuring knee cartilage T 1 , T 2 , and T 1ρ with good agreement with conventional sequences. Evidence Level 1 Technical Efficacy Stage 1
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center of Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
ORCID-Profile: Xiaoxia Zhang, Hector L de Moura, Anmol Monga, Marcelo V W Zibetti, Richard Kijowski, Ravinder R Regatte
Förderung
- NIH HHS
- NIAMS NIH HHS
- NIBIB NIH HHS
- Center of Advanced Imaging Innovation and Research
- NIBIB Biomedical Technology Resource Center
- NYU Grossman School of Medicine
- National Institutes of Health
Zitieren
APA
Zhang, X., de Moura, H. L., Monga, A., Zibetti, M. V. W., Kijowski, R., & Regatte, R. R. (2024). Repeatability of Quantitative Knee Cartilage T 1 , T 2 , and T 1ρ Mapping With 3D‐MRI Fingerprinting. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29068
Vancouver
Zhang X, de Moura HL, Monga A, Zibetti MVW, Kijowski R, Regatte RR. Repeatability of Quantitative Knee Cartilage T 1 , T 2 , and T 1ρ Mapping With 3D‐MRI Fingerprinting. Journal of Magnetic Resonance Imaging. 2024. doi:10.1002/jmri.29068
BibTeX
@article{Zhang2024,
author = {Zhang, Xiaoxia and de Moura, Hector L and Monga, Anmol and Zibetti, Marcelo V W and Kijowski, Richard and Regatte, Ravinder R},
title = {Repeatability of Quantitative Knee Cartilage T 1 , T 2 , and T 1ρ Mapping With 3D‐MRI Fingerprinting},
journal = {Journal of Magnetic Resonance Imaging},
year = {2024},
doi = {10.1002/jmri.29068}
}
EUVIMED