Assessment of Pulmonary Ventilation Using 3D Ventilation Flow Capacity‐Weighted and Ventilation‐Weighted Maps From 3D Ultrashort Echo Time ( UTE ) MRI
Journal of Magnetic Resonance Imaging · 2024
DOI: 10.1002/jmri.29129 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2024. Verfasst von Seokwon Lee und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Pulmonary Disease, Chronic Obstructive, Pulmonary Ventilation, Magnetic Resonance Imaging. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: National Research Foundation of Korea.
Abstract (Originalsprache)
Background
Three‐dimensional (3D) ventilation flow capacity‐weighted (VFCW) maps together with 3D ventilation‐weighted (VW) maps may help to better assess pulmonary function.
Purpose
To investigate the use of 3D VFCW and VW maps for evaluating pulmonary ventilation function. Study Type Prospective. Population Two patients (one male, 85 years old; one female, 64 years old) with chronic obstructive pulmonary disease (COPD) and nine healthy subjects (all male; 23–27 years). Field Strength/Sequence 3‐T, 3D radial UTE imaging. Assessment 3D VFCW and VW maps were calculated from 3D UTE MRI by voxel‐wise subtraction of respiratory phase images. Their validation was tested in nine healthy volunteers using slow/deep and fast/shallow breathing conditions. Additional validation was performed by comparison with single photon emission computed tomography (SPECT) ventilation maps of one healthy participant. For comparison, gravity dependence of anterior–posterior regional ventilation was assessed by one‐dimensional plot of the mean signal intensity for each coronal slice. Structural similarity index measure was also calculated. Finally, VW maps and VFCW maps of two COPD patients were evaluated for emphysema lesions with reference to CT images. Statistical Tests Wilcoxon sign‐rank tests for regional Ventilation and ventilation flow capacity, analysis of variance, post‐hoc t ‐tests and Bonferroni correction, coefficient of variation, Kullback–Liebler divergence. A P ‐value
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
- Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Seoul, Republic of Korea.
- Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea.
ORCID-Profile: Seokwon Lee, Ho Yun Lee, Jinil Park, Hyeonha Kim, Jang-Yeon Park
Förderung
- National Research Foundation of Korea
Zitieren
APA
Lee, S., Lee, H. Y., Park, J., Kim, H., & Park, J. Y. (2024). Assessment of Pulmonary Ventilation Using 3D Ventilation Flow Capacity‐Weighted and Ventilation‐Weighted Maps From 3D Ultrashort Echo Time ( UTE ) MRI. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29129
Vancouver
Lee S, Lee HY, Park J, Kim H, Park JY. Assessment of Pulmonary Ventilation Using 3D Ventilation Flow Capacity‐Weighted and Ventilation‐Weighted Maps From 3D Ultrashort Echo Time ( UTE ) MRI. Journal of Magnetic Resonance Imaging. 2024. doi:10.1002/jmri.29129
BibTeX
@article{Lee2024,
author = {Lee, Seokwon and Lee, Ho Yun and Park, Jinil and Kim, Hyeonha and Park, Jang-Yeon},
title = {Assessment of Pulmonary Ventilation Using 3D Ventilation Flow Capacity‐Weighted and Ventilation‐Weighted Maps From 3D Ultrashort Echo Time ( UTE ) MRI},
journal = {Journal of Magnetic Resonance Imaging},
year = {2024},
doi = {10.1002/jmri.29129}
}
EUVIMED