Quantification of Spatial Ventilation Defect Sparsity in Hyperpolarized Gas Magnetic Resonance Imaging of Lungs Utilizing a Three‐Dimensional Clustering Algorithm
NMR in Biomedicine · 2025
DOI: 10.1002/nbm.70005 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Gabriela María García Delgado und 11 weiteren Autor:innen. Beteiligte Einrichtung: Chemical and Biomedical Engineering, University of Missouri, Columbia, Missouri, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Lung, Algorithms, Imaging, Three-Dimensional. Die Arbeit nennt 24 Literaturangaben. Gefördert von: Xemed, NIH HHS, GlaxoSmithKline.
Abstract (Originalsprache)
Hyperpolarized gas (HPG) magnetic resonance (MR) imaging allows for the quantification of pulmonary defects with the ventilation defect percentage (VDP). Although informative, VDPs lack information regarding the spatial distribution of defects. We developed a method of quantifying the focality/sparseness of ventilation defects in hyperpolarized‐gas lung MR images. The study involved a total of 56 subjects: 14 asthmatics (age mean ± sd = 45.1 ± 18.9), 25 COPD subjects (age = 60.6 ± 10.4), and 17 CF subjects (age = 21.8 ± 8.4). The analyzed data are from four different studies: Study 1 used a 3‐T gradient echo (GRE) sequence, Study 2 used a 1.5‐T GRE sequence, Study 3 used a 1.5‐T two‐dimensional spiral sequence, and Study 4 used a 1.5‐T three‐dimensional balanced steady‐state free precession (bSSFP) sequence. We developed an algorithm that quantifies the focality/sparseness of ventilation defects as a subject's cluster index (CI). The algorithm was assessed on synthesized spherical defect clusters and 3D lung volume defects of varying sizes/distributions. CI and whole‐lung VDP were calculated for asthmatic, COPD, and CF subjects. Pearson correlation coefficients and linear regression models between CI and FEV1pp, as well as CI and VDP, were performed to evaluate CI among asthma, COPD, and CF. T tests were performed to evaluate CI/VDP ratios among previously mentioned lung diseases. p values less than 0.05 were statistically significant. Subject CI well represents defect focality by visual inspection. Pearson correlation coefficients between CI and VDP were r = 0.60 ( p = 2.21 × 10 −2 ) for asthma, r = 0.79 ( p = 3.15 × 10 −6 ) for COPD, and r = 0.84 ( p = 2.80 × 10 −5 ) for CF. Pearson correlation coefficients between CI and FEV1pp was r = −0.47 ( p = 0.0002). Analysis of variance (ANOVA) and a Tukey's honestly significant difference (HSD) test revealed that the ratio of whole‐lung CI/VDP was significantly different between asthma/CF ( p = 0.04) and CF/COPD ( p = 0.008), but not among asthma/COPD ( p = 0.95). This method of volumetric quantification of defect spatial distribution may provide information regarding defect cluster size in which VDP alone is uninformative.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Chemical and Biomedical Engineering, University of Missouri, Columbia, Missouri, USA.
- Biomedical Engineering, School of Engineering, University of Illinois, Chicago, Illinois, USA.
- Radiology, School of Medicine, University of Missouri, Columbia, Missouri, USA.
- Radiology and Medical Imaging, School of Medicine, University of Virginia, Charlottesville, Virginia, USA.
- Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.
- Radiation Oncology, City of Hope, Duarte, California, USA.
ORCID-Profile: Gabriela María García Delgado
Förderung
- Xemed
- NIH HHS
- GlaxoSmithKline
- Vertex Pharmaceuticals
- NHLBI NIH HHS
- National Institutes of Health
Zitieren
APA
García Delgado, G. M., Shammi, U. A., Ruppel, M. R., Altes, T. A., Mugler, J. P., Meyer, C. H., Qing, K., de Lange, E. E., Mata, J., Ruset, I. C., Hersman, F. W., & Thomen, R. P. (2025). Quantification of Spatial Ventilation Defect Sparsity in Hyperpolarized Gas Magnetic Resonance Imaging of Lungs Utilizing a Three‐Dimensional Clustering Algorithm. NMR in Biomedicine. https://doi.org/10.1002/nbm.70005
Vancouver
García Delgado GM, Shammi UA, Ruppel MR, Altes TA, Mugler JP, Meyer CH, et al. Quantification of Spatial Ventilation Defect Sparsity in Hyperpolarized Gas Magnetic Resonance Imaging of Lungs Utilizing a Three‐Dimensional Clustering Algorithm. NMR in Biomedicine. 2025. doi:10.1002/nbm.70005
BibTeX
@article{GarcaDelgado2025,
author = {García Delgado, Gabriela María and Shammi, Ummul Afia and Ruppel, Mia R and Altes, Talissa A and Mugler, John P and Meyer, Craig H and Qing, Kun and de Lange, Eduard E and Mata, Jaime and Ruset, Iulian C and Hersman, F W and Thomen, Robert P},
title = {Quantification of Spatial Ventilation Defect Sparsity in Hyperpolarized Gas Magnetic Resonance Imaging of Lungs Utilizing a Three‐Dimensional Clustering Algorithm},
journal = {NMR in Biomedicine},
year = {2025},
doi = {10.1002/nbm.70005}
}
EUVIMED