EUVIMEDEUVIMED entdecken
Crossref

The size distribution of the agitated saline microbubbles for contrast transcranial Doppler generated using standard manual methods

Zhengbin Pan iD, Yiting Xiao, Zhiyue Wang, Bo Kong, Yiyi Liang

Microscopy Research and Technique · 2024

DOI: 10.1002/jemt.24481 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microscopy Research and Technique, 2024. Verfasst von Zhengbin Pan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, Guangdong Technion-Israel Institute of Technology (GTIIT), Shantou, China. Hauptthemen laut MEDLINE: Microbubbles, Contrast Media. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Shantou Science and Technology Project, Shantou Science and Technology Bureau.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Agitated saline microbubbles (MBs) are a common contrast agent for determining right‐to‐left shunt (RLS) by the contrast transcranial Doppler (c‐TCD). The size of the generated bubbles is not standardized in clinical practice. MBs were generated using the recommended manual method by reciprocating motion through two syringes. The bubble size distributions (BSD) were measured using the microscopic shadow imaging technique. The results show that the diameter of MBs is mainly distributed between 10 and 100 μm, the mean bubble size is between 21 and 34 μm, the Sauter mean diameter (D 32 ) is primarily between 50 and 300 μm, and the standard deviation (SD) is between 6 and 17 μm in 80 experiments. It provides a more accurate basis for the recommended manual method instability. The high variance values of the BSD indicate that the manual method has low stability and repeatability. The results of this study can be useful for further improvement of the reliability of c‐TCD in detecting RLS. Research Highlights This study provided the first detailed descriptions of the MBs size distribution in a flowing contrast agent by the microscopic shadow imaging technique. It reveals significant differences in the bubble size of manual foaming during repeated manipulations for each individual and between individuals.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicrobubblesContrast MediaHumansReproducibility of ResultsUltrasonography, Doppler, Transcranial

Stichwörter der Autor:innen

bubble size distributionsmanualmicrobubblesrepeatability

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Chemical Engineering, Guangdong Technion-Israel Institute of Technology (GTIIT), Shantou, China.
  • Department of Neurology, Guangdong Neuroscience Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University Guangzhou, Guangzhou, China.

ORCID-Profile: Zhengbin Pan

Förderung

  • Shantou Science and Technology Project
  • Shantou Science and Technology Bureau

Zitieren

APA

Pan, Z., Xiao, Y., Wang, Z., Kong, B., & Liang, Y. (2024). The size distribution of the agitated saline microbubbles for contrast transcranial Doppler generated using standard manual methods. Microscopy Research and Technique. https://doi.org/10.1002/jemt.24481

Vancouver

Pan Z, Xiao Y, Wang Z, Kong B, Liang Y. The size distribution of the agitated saline microbubbles for contrast transcranial Doppler generated using standard manual methods. Microscopy Research and Technique. 2024. doi:10.1002/jemt.24481

BibTeX
@article{Pan2024,
  author = {Pan, Zhengbin and Xiao, Yiting and Wang, Zhiyue and Kong, Bo and Liang, Yiyi},
  title = {The size distribution of the agitated saline microbubbles for contrast transcranial Doppler generated using standard manual methods},
  journal = {Microscopy Research and Technique},
  year = {2024},
  doi = {10.1002/jemt.24481}
}
Kostenlos starten →