EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High-frequency ultrasound combined with microbubbles for preoperative lymphatic mapping for lymphedema with a non-linear pattern in indocyanine green lymphography

ShuFang Yuan, LiPing Chen, LanJing Wu, ChenYang Zhao, JingJing Wen, Long Biao Yu, ZheGang Zhou, DeSheng Sun, ZhengMing Hu

European Radiology · 24.01.2026 · 36 (7) · 5243-5252

DOI: 10.1007/s00330-025-12293-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Radiology, erschienen am 24.01.2026. Verfasst von ShuFang Yuan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound Imaging, Peking University Shenzhen Hospital, Shenzhen, China. ysfsue@aliyun.com. Hauptthemen laut MEDLINE: Lymphedema, Indocyanine Green, Lymphography, Lymphatic Vessels. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Sanming Project of Medicine in Shenzhen, National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Lymphatic-venous anastomosis (LVA) is an effective surgical treatment for lymphedema, which requires accurate identification of lymphatic vessels. Indocyanine Green (ICG) lymphography, the most common method for lymphatic mapping, cannot always successfully identify lymphatic vessels. We aimed to explore high-frequency ultrasound (HFUS) and contrast-enhanced ultrasound (CEUS) as a reliable alternative for lymphatic mapping when ICG lymphography is not feasible. Materials and methods We performed combined HFUS and CEUS for lymphatic mapping on the patients who exhibited no obvious linear pattern on ICG lymphography. The inner and outer diameters and depths of the lymphatic vessels were measured. We subsequently evaluated the accuracy of US lymphatic mapping by comparing it with the operative results. And the postoperative volume and circumference of the affected limbs were compared with the preoperative measurements.

Results

We recruited 111 patients with lymphedema, including 96 limbs and 24 perineal areas affected. Three hundred forty-five lymphatics in the limbs and 52 in the perineum underwent anastomosis and were analyzed. Comparable lymphatic vessel diameter (inner: 0.5–0.9 mm; outer: 0.8–0.9 mm) and depth (9-10 mm) measurements across HFUS, CEUS, and combined HFUS + CEUS. However, HFUS + CEUS significantly improved detection sensitivity, identifying 313 vessels (91.1% accuracy) vs 114 (88.6%) for HFUS and 22 (90.9%) for CEUS. Significant postoperative reductions in limb circumference (39.3 ± 7.4 cm to 37.8 ± 7.1 cm) and volume (8.23 ± 3.63 L to 7.52 ± 3.39 L, p < 0.001). All ultrasound methods consistently showed volume reduction (HFUS: 9.37 ± 2.93 L to 8.46 ± 2.01 L; CEUS: 9.46 ± 2.57 L to 9.09 ± 2.45 L; HFUS + CEUS: 9.30 ± 3.21 L to 8.07 ± 3.12 L, p < 0.001–0.002).

Conclusions

High-frequency US combined with CEUS serves as a reliable pre-op lymphatic mapping alternative when ICG lymphography fails. Key Points Question In over 40% of lymphedema patients, preoperative ICG lymphangiography fails to show a linear pattern; can HFUS and CEUS provide complementary information?

Findings

ICG failed to visualize in 42.53% of patients; HFUS and CEUS identified lymphatics in all and achieved 94.5% accuracy . Clinical relevance This study confirmed that HFUS combined with CEUS improves the detection of lymphatic vessels and the success of LVA in ICG-negative cases .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LymphedemaIndocyanine GreenLymphographyLymphatic VesselsMicrobubblesHumansFemaleMaleUltrasonographyMiddle AgedContrast MediaAdultAgedAnastomosis, SurgicalReproducibility of ResultsPreoperative Care

Stichwörter der Autor:innen

Contrast-enhanced ultrasoundIndocyanine greenLymphedemaLymphovenous anastomosisUltrasonography

Substanzen

Indocyanine GreenContrast Media

Autor:innen und Institutionen

  • Department of Ultrasound Imaging, Peking University Shenzhen Hospital, Shenzhen, China. ysfsue@aliyun.com.
  • Department of Ultrasound Imaging, Peking University Shenzhen Hospital, Shenzhen, China.
  • Medical Technology Department, The Islands Healthcare Complex-Macao Medical Center of Peking Union Medical College Hospital, Shenzhen, China.
  • Microsurgery & Lymphatic Surgery Department, Peking University Shenzhen Hospital, Shenzhen, China.
  • Department of Ultrasound Imaging, Peking University Shenzhen Hospital, Shenzhen, China. gooseegg2010@126.com.

Förderung

  • Sanming Project of Medicine in Shenzhen
  • National Key Research and Development Program of China

Zitieren

APA

Yuan, S., Chen, L., Wu, L., Zhao, C., Wen, J., Yu, L. B., Zhou, Z., Sun, D., & Hu, Z. (2026). High-frequency ultrasound combined with microbubbles for preoperative lymphatic mapping for lymphedema with a non-linear pattern in indocyanine green lymphography. European Radiology. https://doi.org/10.1007/s00330-025-12293-7

Vancouver

Yuan S, Chen L, Wu L, Zhao C, Wen J, Yu LB, et al. High-frequency ultrasound combined with microbubbles for preoperative lymphatic mapping for lymphedema with a non-linear pattern in indocyanine green lymphography. European Radiology. 2026. doi:10.1007/s00330-025-12293-7

BibTeX
@article{Yuan2026,
  author = {Yuan, ShuFang and Chen, LiPing and Wu, LanJing and Zhao, ChenYang and Wen, JingJing and Yu, Long Biao and Zhou, ZheGang and Sun, DeSheng and Hu, ZhengMing},
  title = {High-frequency ultrasound combined with microbubbles for preoperative lymphatic mapping for lymphedema with a non-linear pattern in indocyanine green lymphography},
  journal = {European Radiology},
  year = {2026},
  doi = {10.1007/s00330-025-12293-7}
}
Kostenlos starten →