Inverse Problem Approach to Aberration Correction for In Vivo Transcranial Imaging Based on a Sparse Representation of Contrast-Enhanced Ultrasound Data
IEEE Transactions on Biomedical Engineering · 2025
DOI: 10.1109/tbme.2025.3564473 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2025. Verfasst von Paul Xing und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Contrast Media, Image Processing, Computer-Assisted, Ultrasonography, Doppler, Transcranial. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: Institut TransMedTech, Natural Sciences and Engineering Research Council of Canada NSERC, Mitacs accelerate fellowship.
Abstract (Originalsprache)
OBJECTIVE: Transcranial ultrasound imaging is currently limited by attenuation and aberration induced by the skull. First used in contrast-enhanced ultrasound (CEUS), highly echoic microbubbles allowed for the development of novel imaging modalities such as ultrasound localization microscopy (ULM). Herein, we develop an inverse problem approach to aberration correction (IPAC) that leverages the sparsity of microbubble signals. METHODS: We propose to use the a priori knowledge of the medium based upon microbubble localization and wave propagation to build a forward model to link the measured signals directly to the aberration function. A standard least-squares inversion is then used to retrieve the aberration function. We first validated IPAC on simulated data of a vascular network using plane wave as well as divergent wave emissions. We then evaluated the reproducibility of IPAC in vivo in 5 mouse brains. RESULTS: We showed that aberration correction improved the contrast of CEUS images by 4.6 dB. For ULM images, IPAC yielded sharper vessels, reduced vessel duplications, and improved the resolution from 21.1 $\mu$m to 18.3 $\mu$m. Aberration correction also improved hemodynamic quantification for velocity magnitude and flow direction. CONCLUSION: We showed that IPAC can perform skull-induced aberration correction and improved power Doppler as well as ULM images acquired on the mouse brain. SIGNIFICANCE: This technique is promising for more reliable transcranial imaging of the brain vasculature with potential non-invasive clinical applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Förderung
- Institut TransMedTech
- Natural Sciences and Engineering Research Council of Canada NSERC
- Mitacs accelerate fellowship
- Canada Foundation for Innovation
- Canadian Institutes of Health Research
- Natural Sciences and Engineering Research Council of Canada
- Canada Research Chair in neurovascular interactions
- Calcul Québec
Zitieren
APA
Xing, P., Malescot, A., Martineau, E., Rungta, R. L., & Provost, J. (2025). Inverse Problem Approach to Aberration Correction for In Vivo Transcranial Imaging Based on a Sparse Representation of Contrast-Enhanced Ultrasound Data. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2025.3564473
Vancouver
Xing P, Malescot A, Martineau E, Rungta RL, Provost J. Inverse Problem Approach to Aberration Correction for In Vivo Transcranial Imaging Based on a Sparse Representation of Contrast-Enhanced Ultrasound Data. IEEE Transactions on Biomedical Engineering. 2025. doi:10.1109/tbme.2025.3564473
BibTeX
@article{Xing2025,
author = {Xing, Paul and Malescot, Antoine and Martineau, Eric and Rungta, Ravi L and Provost, Jean},
title = {Inverse Problem Approach to Aberration Correction for In Vivo Transcranial Imaging Based on a Sparse Representation of Contrast-Enhanced Ultrasound Data},
journal = {IEEE Transactions on Biomedical Engineering},
year = {2025},
doi = {10.1109/tbme.2025.3564473}
}
EUVIMED