Stability of glycated haemoglobin ( HbA1c ) measurements from whole blood samples kept at −196°C for seven to eight years in The Malaysian Cohort study
Journal of Clinical Laboratory Analysis · 2023
DOI: 10.1002/jcla.24898 ↗Kurz gefasst
Kohortenstudie in der Zeitschrift Journal of Clinical Laboratory Analysis, 2023. Verfasst von Noraidatulakma Abdullah und 10 weiteren Autor:innen. Beteiligte Einrichtung: UKM Medical Molecular Biology Institute (UMBI), Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia. Hauptthemen laut MEDLINE: Diabetes Mellitus, Type 2, Diabetes Mellitus. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Ministry of Higher Education, Malaysia, Universiti Kebangsaan Malaysia.
Abstract (Originalsprache)
Objective
Glycated haemoglobin (HbA1c) is a standard indication for screening type 2 diabetes that also has been widely used in large‐scale epidemiological studies. However, its long‐term quality (in terms of reproducibility) stored in liquid nitrogen is still unknown. This study is aimed to evaluate the stability and reproducibility of HbA1c measurements from frozen whole blood samples kept at −196°C for more than 7 years.
Methods
A total of 401 whole blood samples with a fresh HbA1c measurement were randomly selected from The Malaysian Cohort's (TMC) biobank. The HbA1c measurements of fresh and frozen (stored for 7–8 years) samples were assayed using different high‐performance liquid chromatography (HPLC) systems. The HbA1c values of the fresh samples were then calculated and corrected according to the later system. The reproducibility of HbA1c measurements between calculated‐fresh and frozen samples was assessed using a Passing‐Bablok linear regression model. The Bland–Altman plot was then used to evaluate the concordance of HbA1c values.
Results
The different HPLC systems highly correlated ( r = 0.99) and agreed (ICC = 0.96) with each other. Furthermore, the HbA1c measurements for frozen samples strongly correlate with the corrected HbA1c values of the fresh samples ( r = 0.875) with a mean difference of −0.02 (SD: −0.38 to 0.38). Although the mean difference is small, discrepancies were observed within the diabetic and non‐diabetic samples.
Conclusion
These data demonstrate that the HbA1c measurements between fresh and frozen samples are highly correlated and reproducible.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- UKM Medical Molecular Biology Institute (UMBI), Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia.
ORCID-Profile: Noraidatulakma Abdullah, Ying-Xian Goh
Förderung
- Ministry of Higher Education, Malaysia
- Universiti Kebangsaan Malaysia
Zitieren
APA
Abdullah, N., Goh, Y. X., Othman, R., Ismail, N., Jalal, N., Wan Sallam, W. A. F., Husin, N. F., Shafie, A. S., Awang, A., Kamaruddin, M. A., & Jamal, R. (2023). Stability of glycated haemoglobin ( HbA1c ) measurements from whole blood samples kept at −196°C for seven to eight years in The Malaysian Cohort study. Journal of Clinical Laboratory Analysis. https://doi.org/10.1002/jcla.24898
Vancouver
Abdullah N, Goh YX, Othman R, Ismail N, Jalal N, Wan Sallam WAF, et al. Stability of glycated haemoglobin ( HbA1c ) measurements from whole blood samples kept at −196°C for seven to eight years in The Malaysian Cohort study. Journal of Clinical Laboratory Analysis. 2023. doi:10.1002/jcla.24898
BibTeX
@article{Abdullah2023,
author = {Abdullah, Noraidatulakma and Goh, Ying-Xian and Othman, Raihannah and Ismail, Norliza and Jalal, Nazihah and Wan Sallam, Wan Ahmad Faisal and Husin, Nurul Faeizah and Shafie, Ahmad Syafiq and Awang, Afifah and Kamaruddin, Mohd Arman and Jamal, Rahman},
title = {Stability of glycated haemoglobin ( HbA1c ) measurements from whole blood samples kept at −196°C for seven to eight years in The Malaysian Cohort study},
journal = {Journal of Clinical Laboratory Analysis},
year = {2023},
doi = {10.1002/jcla.24898}
}
EUVIMED