Interference of Hb J-Sardegna on HbA1c Quantification in a Diabetic Patient
Clinical Laboratory · 2026
DOI: 10.7754/clin.lab.2025.250556 ↗Kurz gefasst
Fallbericht in der Zeitschrift Clinical Laboratory, 2026. Verfasst von Li Liang und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Diabetes Mellitus, Diabetes Mellitus, Type 2, Glycated Hemoglobin, Hemoglobin J.
Abstract (Originalsprache)
BACKGROUND: Hb J-Sardegna represents a rare hemoglobin (Hb) variant with no previously documented interference in HbA1c quantification. In this study, we report the first case of Hb J-Sardegna incidentally identified in a diabetic patient, demonstrating significant discordance between measured blood glucose levels and disproportionately elevated HbA1c values. METHODS: The patient presented to our institution for follow-up evaluation of thyroid nodules, during which diabetes screening was clinically indicated. Plasma glucose levels were measured using biochemical analyzers, while HbA1c quantification was performed by high-performance liquid chromatography (HPLC). Hb fractions analysis was conducted by capillary electrophoresis (CE), with subsequent confirmation of the suspected variant through Sanger sequencing. RESULTS: Laboratory investigations revealed markedly elevated glucose levels (fasting: 8.79 mmol/L; 2-hour postprandial: 18.09 mmol/L), while HPLC analysis demonstrated a discordantly elevated HbA1c of 32.23%. CE identified an abnormal Hb fraction (Hb J peak: 31.8%), with subsequent Sanger sequencing confirming the presence of Hb J-Sardegna (HBA2:c.151C>G) and the intronic variant IVS-II-89T>C (HBA1:c.301-61T>C). Notably, all hematological parameters remained within normal ranges. CONCLUSIONS: This study reports for the first time that Hb J-Sardegna can interfere with HbA1c quantification, highlighting the importance for laboratory technicians to carefully interpret chromatographic profiles when analyzing HbA1c results.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Zitieren
APA
Liang, L., Zheng, L., Du, Y., Liang, L., & Li, Y. (2026). Interference of Hb J-Sardegna on HbA1c Quantification in a Diabetic Patient. Clinical Laboratory. https://doi.org/10.7754/clin.lab.2025.250556
Vancouver
Liang L, Zheng L, Du Y, Liang L, Li Y. Interference of Hb J-Sardegna on HbA1c Quantification in a Diabetic Patient. Clinical Laboratory. 2026. doi:10.7754/clin.lab.2025.250556
BibTeX
@article{Liang2026,
author = {Liang, Li and Zheng, Lihong and Du, Yongguang and Liang, Liang and Li, Youqiong},
title = {Interference of Hb J-Sardegna on HbA1c Quantification in a Diabetic Patient},
journal = {Clinical Laboratory},
year = {2026},
doi = {10.7754/clin.lab.2025.250556}
}
EUVIMED