EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Tin Silver Alloy as a Biomaterial: Corrosion Characteristics and Cellular Behavior

Charley M Goodwin, Annsley O Mace, Jeremy L Gilbert iD

Journal of Biomedical Materials Research Part A · 2025-01 · 113 (1)

DOI: 10.1002/jbm.a.37822 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomedical Materials Research Part A, online erschienen am 29.10.2024. Verfasst von Charley M Goodwin und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, Clemson University, Clemson, South Carolina, USA. Hauptthemen laut MEDLINE: Silver, Biocompatible Materials, Alloys, Tin. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Wyss Foundation, Bayer.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Tin‐silver (Sn‐Ag) has been used as a permanently implanted biomaterial within the Essure female sterilization device and in dental amalgams; however, little data exist for Sn‐Ag's corrosion characteristics and/or cellular interactions. In this study, to assess its suitability as a degradable metallic biomaterial, 95–5 wt% Sn‐Ag solder was subjected to corrosion testing including open circuit potential (OCP), electrochemical impedance spectroscopy (EIS), and anodic potentiodynamic polarization in phosphate‐buffered saline (PBS) and cell culture media (with serum proteins) at room temperature (25°C) and body temperature (37°C). Cell culture studies were also performed. Mouse pre‐osteoblast cells (MC3T3‐E1) were cultured in media on Sn‐Ag discs and monitored over 24 h at potentials below, around, or above Sn‐Ag's breakdown potential, fixed, and then viewed using SEM. Separately, cells on tissue culture plastic were subjected to increasing concentrations of SnCl 2 in media for 24 h before a live‐dead imaging at each concentration to determine cell viability and area fraction covered when compared with a control well. The results show both passive (in PBS), with a breakdown potential of −250 mV versus Ag/AgCl and active polarization behavior (in AMEM with proteins). EIS results showed polarization resistance ( R p ) in the 10 5 Ωcm 2 range but decreased generally with increasing temperature ( p < 0.05). Cells were well attached on Sn‐Ag surfaces at OCP and below the breakdown potential, but when anodically polarized, cells reduced their spread area and became more spherical, indicating less viability. SnCl 2 exhibited a dose‐dependent killing effect on MC3T3 cells with a lethal dose for 50% of about 0.5 mM. The results of these experiments show that Sn‐Ag alloys can be considered as degradable metallic biomaterials.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SilverBiocompatible MaterialsAlloysTinAnimalsMiceCorrosionCell SurvivalMaterials TestingCell LineOsteoblastsDielectric Spectroscopy

Stichwörter der Autor:innen

biodegradable alloycytocompatibilitypolarizationtin‐silver

Substanzen

SilverBiocompatible MaterialsAlloysTin

Autor:innen und Institutionen

  • Department of Bioengineering, Clemson University, Clemson, South Carolina, USA.
  • Clemson - Medical University of South Carolina Bioengineering Program, Charleston, South Carolina, USA.

ORCID-Profile: Jeremy L Gilbert

Förderung

  • Wyss Foundation
  • Bayer

Zitieren

APA

Goodwin, C. M., Mace, A. O., & Gilbert, J. L. (2025). Tin Silver Alloy as a Biomaterial: Corrosion Characteristics and Cellular Behavior. Journal of Biomedical Materials Research Part A, 113(1). https://doi.org/10.1002/jbm.a.37822

Vancouver

Goodwin CM, Mace AO, Gilbert JL. Tin Silver Alloy as a Biomaterial: Corrosion Characteristics and Cellular Behavior. Journal of Biomedical Materials Research Part A. 2025;113(1). doi:10.1002/jbm.a.37822

BibTeX
@article{Goodwin2025,
  author = {Goodwin, Charley M and Mace, Annsley O and Gilbert, Jeremy L},
  title = {Tin Silver Alloy as a Biomaterial: Corrosion Characteristics and Cellular Behavior},
  journal = {Journal of Biomedical Materials Research Part A},
  year = {2025},
  volume = {113},
  number = {1},
  doi = {10.1002/jbm.a.37822}
}
Kostenlos starten →