EUVIMEDEUVIMED entdecken
Crossref

Degradation Characteristics and Biocompatibility of Zinc Alloy in Advanced Biomedical Bone Implants

Saiyu Liu iD, Chaoying Yuan, Kewei Gao, Rongjian Shi, Bin Zhu iD, Xiaolu Pang iD

Langmuir · 2025

DOI: 10.1021/acs.langmuir.4c05260 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Langmuir, 2025. Verfasst von Saiyu Liu und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, China. Hauptthemen laut MEDLINE: Zinc, Alloys, Biocompatible Materials, Prostheses and Implants. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 57 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Beijing Municipal Science and Technology Commission, University of Science and Technology Beijing.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Biodegradable zinc-based alloys are regarded as a promising avenue of research for the development of bone fixation implants, offering potential solutions to clinical issues, such as stress shielding, secondary surgeries, and biocompatibility. In this study, a Zn-0.8Li-0.4Mg alloy was designed and fabricated and its potential for use as a clinical bone implant was evaluated. The alloy displays an ultimate tensile strength of 450 MPa and an elongation of 18%, thereby satisfying the requisite mechanical specifications for clinical bone implants. The results of the electrochemical and SBF in vitro corrosion tests indicate that the degradation mechanism evolves over time. The initial corrosion product layer is composed of a dense Li-containing corrosion product (LiOH/Li2CO3), which subsequently transforms into an Mg-containing corrosion product layer (MgO/Mg(OH)2) as corrosion progresses. Ultimately, due to the depletion of Li and the erosion by Cl-, it transitions to a corrosion product layer containing only the Zn and Ca/P layer. The overall degradation mechanism is jointly determined by the degree of local degradation and the corrosion resistance of the product layer. Cytotoxicity tests demonstrate that the Zn-0.8Li-0.4Mg alloy exhibits favorable biocompatibility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ZincAlloysBiocompatible MaterialsProstheses and ImplantsCorrosionAnimalsMaterials TestingMiceCell Survival

Substanzen

ZincAlloysBiocompatible Materials

Autor:innen und Institutionen

  • School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, China.
  • Department of Orthopedics, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China.
  • State Key Laboratory of Nuclear Power Safety Technology and Equipment, University of Science and Technology Beijing, Beijing 100083, China.

ORCID-Profile: Saiyu Liu, Bin Zhu, Xiaolu Pang

Förderung

  • National Natural Science Foundation of China
  • Beijing Municipal Science and Technology Commission
  • University of Science and Technology Beijing

Zitieren

APA

Liu, S., Yuan, C., Gao, K., Shi, R., Zhu, B., & Pang, X. (2025). Degradation Characteristics and Biocompatibility of Zinc Alloy in Advanced Biomedical Bone Implants. Langmuir. https://doi.org/10.1021/acs.langmuir.4c05260

Vancouver

Liu S, Yuan C, Gao K, Shi R, Zhu B, Pang X. Degradation Characteristics and Biocompatibility of Zinc Alloy in Advanced Biomedical Bone Implants. Langmuir. 2025. doi:10.1021/acs.langmuir.4c05260

BibTeX
@article{Liu2025,
  author = {Liu, Saiyu and Yuan, Chaoying and Gao, Kewei and Shi, Rongjian and Zhu, Bin and Pang, Xiaolu},
  title = {Degradation Characteristics and Biocompatibility of Zinc Alloy in Advanced Biomedical Bone Implants},
  journal = {Langmuir},
  year = {2025},
  doi = {10.1021/acs.langmuir.4c05260}
}
Kostenlos starten →