EUVIMEDEUVIMED entdecken
Crossref

Effect of surface treatment of NiTi alloy on its corrosion behavior in Hanks’ solution

O Cissé, O Savadogo, M Wu, L'H Yahia

Journal of Biomedical Materials Research · 05.09.2002 · 61 (3) · 339-345

DOI: 10.1002/jbm.10114 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomedical Materials Research, online erschienen am 29.04.2002. Verfasst von O Cissé und 3 weiteren Autor:innen. Beteiligte Einrichtung: Laboratoire d'Electrochimie et de Matériaux énergétiques, Ecole Polytechnique Montréal, C.P. 76079, succursale centre-ville, Québec H3C 3A7, Canada. Hauptthemen laut MEDLINE: Materials Testing. Die Arbeit wurde bisher 131-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: NSERC (Canada), FCAR (Quebec), The CHUM Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The effect of surface modification of NiTi shape memory alloy on its corrosion behavior in Hanks’ solution was determined. The near‐equi‐atomic super elastic NiTi (Ni 55.8 wt %) alloy used for this study was provided by Memry USA. The surfaces of heat‐treated samples were modified by mechanical polishing (MP), electropolishing (EP), and electropolishing followed by chemical passivation (CP). As‐heat‐treated samples with straw‐colored oxide finishes (SCO) and blue‐colored oxide finishes (BO) also were included in the study. Surface analysis was performed using auger electron spectroscopy (AES), atomic force microscopy (AFM), and contact angle measurements (CAM). It was shown that surface roughness increased in the order CP < EP < SCO < BO < MP. The nickel release within the five groups of NiTi samples, as determined by atomic absorption spectrophotometry, reduced in time over the measured period. The level of Ni ions released over a 25‐day immersion period was highest in the SCO sample (0.002 μg/day). This Ni level is negligible compared with the daily intake of Ni in an ordinary diet. The auger electron spectroscopy (AES) analyses indicated that before immersion in Hanks’ physiologic solution, the main surface composition of all the samples was titanium and nickel, with a small amount of oxygen, carbon, and sulphur as contaminants. And the surface oxide thickness of the different samples increased in the order CP < EP < MP < BO < SCO. On the other hand, for the electrodes treated under the same conditions, the mean breakdown potential value decreased in the order BO > MP > CP > EP > SCO while the corrosion current density and rate increased in the order CP < SCO < EP < BO < MP. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 61: 339–345, 2002

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Materials TestingAlloysCorrosionIsotonic SolutionsMicroscopy, Atomic ForceMicroscopy, ElectronNickelProstheses and ImplantsSpectrophotometry, AtomicSurface PropertiesTitanium

Substanzen

AlloysHanks Balanced Salt SolutionIsotonic SolutionsNickelTitanium

Autor:innen und Institutionen

  • Laboratoire d'Electrochimie et de Matériaux énergétiques, Ecole Polytechnique Montréal, C.P. 76079, succursale centre-ville, Québec H3C 3A7, Canada.

Förderung

  • NSERC (Canada)
  • FCAR (Quebec)
  • The CHUM Foundation

Zitieren

APA

Cissé, O., Savadogo, O., Wu, M., & Yahia, L. (2002). Effect of surface treatment of NiTi alloy on its corrosion behavior in Hanks’ solution. Journal of Biomedical Materials Research, 61(3), 339-345. https://doi.org/10.1002/jbm.10114

Vancouver

Cissé O, Savadogo O, Wu M, Yahia L. Effect of surface treatment of NiTi alloy on its corrosion behavior in Hanks’ solution. Journal of Biomedical Materials Research. 2002;61(3):339-345. doi:10.1002/jbm.10114

BibTeX
@article{Ciss2002,
  author = {Cissé, O and Savadogo, O and Wu, M and Yahia, L'H},
  title = {Effect of surface treatment of NiTi alloy on its corrosion behavior in Hanks’ solution},
  journal = {Journal of Biomedical Materials Research},
  year = {2002},
  volume = {61},
  number = {3},
  pages = {339--345},
  doi = {10.1002/jbm.10114}
}