Influence of corrosion behavior of Ti-based PVD coatings on 316L SS for biomedical implants
Bio-Medical Materials and Engineering · 2026-11 · 37 (6) · 285-302
DOI: 10.1177/09592989261485537 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bio-Medical Materials and Engineering, online erschienen am 04.09.2026. Verfasst von M Shunmuga Priyan und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Loyola Institute of Technology & Science, Thovalai, India. Hauptthemen laut MEDLINE: Titanium, Coated Materials, Biocompatible, Stainless Steel, Prostheses and Implants. Die Arbeit nennt 22 Literaturangaben.
Abstract (Originalsprache)
Background
316L stainless steel (SS) is widely used in biomedical implant applications because of its excellent mechanical properties, corrosion resistance, biocompatibility, and cost-effectiveness. However, its long-term performance in physiological environments is limited by localized corrosion, ion release, and inadequate surface interactions with biological tissues. Surface modification using Ti-based physical vapor deposition (PVD) coatings has emerged as a promising strategy to enhance the corrosion resistance and durability of implant materials.
Objective
This study aimed to investigate the effect of Ti-based PVD coatings, namely TiCoCr, TiN, and TiO 2 , on the corrosion behavior of 316L SS under simulated physiological conditions.
Methods
TiCoCr, TiN, and TiO 2 coatings were deposited onto 316L SS substrates using the PVD technique. The corrosion performance of the coated and uncoated samples was evaluated in phosphate-buffered saline (PBS), Hanks’ solution, and Ringer's solution at 37 °C. Electrochemical corrosion parameters, including corrosion potential and corrosion current density, were analyzed to assess the effectiveness of the coatings.
Results
All Ti-based coatings improved the corrosion resistance of 316L SS compared with the uncoated substrate. Among the investigated coatings, the TiCoCr coating deposited for 90 min exhibited the best corrosion performance. In Ringer's solution, the coating showed a corrosion potential of −0.0504 V and a corrosion current density of 4.74 × 10 −6 A/cm 2 . In Hanks’ solution, the same coating demonstrated a corrosion potential of −0.1815 V and a corrosion current density of 5.0537 × 10 −6 A/cm 2 . The enhanced corrosion resistance was attributed to the protective and stable nature of the Ti-based coating layer.
Conclusion
The TiCoCr, TiN, and TiO 2 PVD coatings significantly enhanced the corrosion resistance of 316L SS in simulated physiological environments. Among them, the TiCoCr coating demonstrated superior corrosion protection, indicating its strong potential for improving the long-term reliability and performance of biomedical implants.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Mechanical Engineering, Loyola Institute of Technology & Science, Thovalai, India.
ORCID-Profile: M Shunmuga Priyan
Zitieren
APA
Shunmuga Priyan, M., & Godwin, G. (2026). Influence of corrosion behavior of Ti-based PVD coatings on 316L SS for biomedical implants. Bio-Medical Materials and Engineering, 37(6), 285-302. https://doi.org/10.1177/09592989261485537
Vancouver
Shunmuga Priyan M, Godwin G. Influence of corrosion behavior of Ti-based PVD coatings on 316L SS for biomedical implants. Bio-Medical Materials and Engineering. 2026;37(6):285-302. doi:10.1177/09592989261485537
BibTeX
@article{ShunmugaPriyan2026,
author = {Shunmuga Priyan, M and Godwin, G},
title = {Influence of corrosion behavior of Ti-based PVD coatings on 316L SS for biomedical implants},
journal = {Bio-Medical Materials and Engineering},
year = {2026},
volume = {37},
number = {6},
pages = {285--302},
doi = {10.1177/09592989261485537}
}
EUVIMED