An FBG ‐based optical pressure sensor for the measurement of radial artery pulse pressure
Journal of Biophotonics · 2024
DOI: 10.1002/jbio.202400083 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biophotonics, 2024. Verfasst von Ranjith B Gowda und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics & Communication Engineering, SOE, Dayananda Sagar University, Bangalore, India. Hauptthemen laut MEDLINE: Radial Artery. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 61 Literaturangaben. Gefördert von: Author ANA acknowledges Researchers Supporting Project number (RSP2024R304), King Saud University, Riyadh, Saudi Arabia.
Abstract (Originalsprache)
One of the diagnostic tool for clinical evaluation and disease diagnosis is a pulse waveform analysis. High fidelity radial artery pulse waveforms have been investigated in clinical research to compute central aortic pressure, which has been demonstrated to be predictive of cardiovascular diseases. The radial artery must be inspected from several angles in order to obtain the best pulse waveform for estimate and diagnosis. In this study, we present the design and experimental testing of an optical sensor based on Fiber Bragg Gratings (FBG). A 3D printed device along with the FBG is used to measure the radial artery pulses. The proposed sensor is used for the purpose of quantifying the radial artery pulse waveform across major pulse position point. The suggested optical sensing system can measure the pulse signal with good accuracy. The main characteristic parameters of the pulse can then be retrieved from the processed signal for their use in clinical applications. By conducting experiments under the direction of medical experts, the pulse signals are measured. In order to experimentally validate the sensor, we used it to detect the pulse waveforms at Guan position of the wrist's radial artery in accordance with the diagnostic standards. The findings show that combining optical technologies for physiological monitoring and radial artery pulse waveform monitoring using FBG in clinical applications are highly feasible.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electronics & Communication Engineering, SOE, Dayananda Sagar University, Bangalore, India.
- Department of Electronics & Communication Engineering, Government Polytechnic Sorab, Shimoga, India.
- Department of Electronics & Communication Engineering, The Oxford College of Engineering, Bangalore, India.
- Department of Physics and Astronomy, College of Science, King Saud University, Riyadh, Saudi Arabia.
ORCID-Profile: Ranjith B Gowda, Preeta Sharan, Abdullah N Alodhayb
Förderung
- Author ANA acknowledges Researchers Supporting Project number (RSP2024R304), King Saud University, Riyadh, Saudi Arabia
Zitieren
APA
Gowda, R. B., Sharan, P., Saara K, Braim, M., & Alodhayb, A. N. (2024). An FBG ‐based optical pressure sensor for the measurement of radial artery pulse pressure. Journal of Biophotonics. https://doi.org/10.1002/jbio.202400083
Vancouver
Gowda RB, Sharan P, Saara K, Braim M, Alodhayb AN. An FBG ‐based optical pressure sensor for the measurement of radial artery pulse pressure. Journal of Biophotonics. 2024. doi:10.1002/jbio.202400083
BibTeX
@article{Gowda2024,
author = {Gowda, Ranjith B and Sharan, Preeta and Saara K and Braim, Mona and Alodhayb, Abdullah N},
title = {An FBG ‐based optical pressure sensor for the measurement of radial artery pulse pressure},
journal = {Journal of Biophotonics},
year = {2024},
doi = {10.1002/jbio.202400083}
}
EUVIMED