EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudie

Invasive Blood Pressure Monitoring Using Ultrasound-guided Artery Cannulation Through the Distal Radial Artery Approach at the Anatomical Snuffbox Compared With the Conventional Artery Approach: A Randomized Controlled Trial

Weijuan Zhu, Ruoxing Chen, Xiaoxiao Cheng, Chufan Liu, Sisi Chen, Hongfei Chen

Journal of Cardiothoracic and Vascular Anesthesia · 2026-08 · 40 (8) · 2325-2331

DOI: 10.1053/j.jvca.2026.03.038 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2026-08. Verfasst von Weijuan Zhu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, the First Affiliated Hospital, Wenzhou Medical University, Zhejiang, China. Hauptthemen laut MEDLINE: Radial Artery, Ultrasonography, Interventional, Catheterization, Peripheral, Blood Pressure Determination. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 15 Literaturangaben. Gefördert von: Wenzhou Municipal Science and Technology Bureau.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE To evaluate the feasibility of ultrasound-guided radial artery cannulation in the anatomical snuffbox for invasive blood pressure monitoring. Invasive blood pressure monitoring is essential for the management of critically ill patients. The conventional radial artery and dorsalis pedis artery are standard access sites; nevertheless, they present limitations. Recently, distal transradial access has become a promising new approach, due to its association with fewer complications and greater patient comfort. DESIGN A randomized controlled study. SETTING May 1, 2023, to May 1, 2024. PARTICIPANTS A total of 120 patients scheduled for invasive blood pressure monitoring via arterial cannulation. INTERVENTIONS Patients were enrolled and randomized into three groups according to the puncture site: radial artery in the anatomical snuffbox (Group A), radial artery (Group B), and dorsalis pedis artery (Group C). MEASUREMENTS AND MAIN RESULTS The coprimary outcomes were the first-attempt success rate and puncture duration. CONCLUSIONS No significant difference was observed in first-attempt success rates among the three groups (Group A: 75%, Group B: 72.5%, and Group C: 52.5%). Group B demonstrated significantly shorter puncture duration than both Group A (p = 0.001) and Group C (p = 0.001). Compared with conventional radial artery and dorsalis pedis artery cannulation, the anatomical snuffbox approach achieves comparable success rates, establishing it as a clinically viable alternative for invasive hemodynamic monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radial ArteryUltrasonography, InterventionalCatheterization, PeripheralBlood Pressure DeterminationHumansFemaleMaleMiddle AgedAgedBlood Pressure

Stichwörter der Autor:innen

artery cannulationdistal radial arteryinvasive blood pressureultrasound guidance

Autor:innen und Institutionen

  • Department of Anesthesiology, the First Affiliated Hospital, Wenzhou Medical University, Zhejiang, China.
  • Operation Room Nursing, the First Affiliated Hospital, Wenzhou Medical University, Zhejiang, China.
  • Department of Pain Management, the First Affiliated Hospital, Wenzhou Medical University, Zhejiang, China. Electronic address: chhfei@126.com.

Förderung

  • Wenzhou Municipal Science and Technology Bureau

Zitieren

APA

Zhu, W., Chen, R., Cheng, X., Liu, C., Chen, S., & Chen, H. (2026). Invasive Blood Pressure Monitoring Using Ultrasound-guided Artery Cannulation Through the Distal Radial Artery Approach at the Anatomical Snuffbox Compared With the Conventional Artery Approach: A Randomized Controlled Trial. Journal of Cardiothoracic and Vascular Anesthesia, 40(8), 2325-2331. https://doi.org/10.1053/j.jvca.2026.03.038

Vancouver

Zhu W, Chen R, Cheng X, Liu C, Chen S, Chen H. Invasive Blood Pressure Monitoring Using Ultrasound-guided Artery Cannulation Through the Distal Radial Artery Approach at the Anatomical Snuffbox Compared With the Conventional Artery Approach: A Randomized Controlled Trial. Journal of Cardiothoracic and Vascular Anesthesia. 2026;40(8):2325-2331. doi:10.1053/j.jvca.2026.03.038

BibTeX
@article{Zhu2026,
  author = {Zhu, Weijuan and Chen, Ruoxing and Cheng, Xiaoxiao and Liu, Chufan and Chen, Sisi and Chen, Hongfei},
  title = {Invasive Blood Pressure Monitoring Using Ultrasound-guided Artery Cannulation Through the Distal Radial Artery Approach at the Anatomical Snuffbox Compared With the Conventional Artery Approach: A Randomized Controlled Trial},
  journal = {Journal of Cardiothoracic and Vascular Anesthesia},
  year = {2026},
  volume = {40},
  number = {8},
  pages = {2325--2331},
  doi = {10.1053/j.jvca.2026.03.038}
}
Kostenlos starten →