EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fiber Bragg Grating Pulse and Systolic Blood Pressure Measurement System Based on Mach–Zehnder Interferometer

Yuanjun Li, Bo Wang, Shanren Liu, Mengmeng Gao, Qianhua Li, Chao Chen iD, Qi Guo, Yongsen Yu

Sensors · 26.09.2024 · 24 (19) · 6222

DOI: 10.3390/s24196222 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 26.09.2024. Verfasst von Yuanjun Li und 7 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012, China. Hauptthemen laut MEDLINE: Interferometry, Blood Pressure, Blood Pressure Determination. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A fiber Bragg grating (FBG) pulse and systolic blood pressure (SBP) measurement system based on the edge-filtering method is proposed. The edge filter is the Mach–Zehnder interferometer (MZI) fabricated by two fiber couplers with a linear slope of 52.45 dBm/nm. The developed system consists of a broadband light source, an edge filter, fiber Bragg gratings (FBGs), a coarse wavelength-division multiplexer (CWDM), and signal-processing circuits based on a field-programmable gate array (FPGA). It can simultaneously measure pulse pulsations of the radial artery in the wrist at three positions: Cun, Guan and Chi. The SBP can be calculated based on the pulse transit time (PTT) principle. The measurement results compared to a standard blood pressure monitor showed the mean absolute error (MAE) and standard deviation (STD) of the SBP were 0.93 ± 3.13 mmHg. The system meets the requirements of the Association for the Advancement of Medical Instrumentation (AAMI) equipment standards. The proposed system can achieve continuous real-time measurement of pulse and SBP and has the advantages of fast detection speed, stable performance, and no compression sensation for subjects. The system has important application value in the fields of human health monitoring and medical device development.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

InterferometryBlood PressureBlood Pressure DeterminationHumansPulse Wave AnalysisSignal Processing, Computer-AssistedOptical FibersEquipment Design

Stichwörter der Autor:innen

edge filterfiber Bragg gratingpulsesystolic blood pressure

Autor:innen und Institutionen

  • State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012, China.
  • State Key Laboratory of Luminescence Science and Technology, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.

ORCID-Profile: Chao Chen

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Li, Y., Wang, B., Liu, S., Gao, M., Li, Q., Chen, C., Guo, Q., & Yu, Y. (2024). Fiber Bragg Grating Pulse and Systolic Blood Pressure Measurement System Based on Mach–Zehnder Interferometer. Sensors, 24(19), 6222. https://doi.org/10.3390/s24196222

Vancouver

Li Y, Wang B, Liu S, Gao M, Li Q, Chen C, et al. Fiber Bragg Grating Pulse and Systolic Blood Pressure Measurement System Based on Mach–Zehnder Interferometer. Sensors. 2024;24(19):6222. doi:10.3390/s24196222

BibTeX
@article{Li2024,
  author = {Li, Yuanjun and Wang, Bo and Liu, Shanren and Gao, Mengmeng and Li, Qianhua and Chen, Chao and Guo, Qi and Yu, Yongsen},
  title = {Fiber Bragg Grating Pulse and Systolic Blood Pressure Measurement System Based on Mach–Zehnder Interferometer},
  journal = {Sensors},
  year = {2024},
  volume = {24},
  number = {19},
  pages = {6222},
  doi = {10.3390/s24196222}
}
Kostenlos starten →