EUVIMEDEUVIMED entdecken
Crossref

A Simple and Affordable CZE–UV Method for Quality Control of Insulin in Active Pharmaceutical Ingredient and Formulations Using Quadruple Polymer‐Coated Capillary

Hailekiros Gebretsadik Kidanemariam, Erwin Adams, Ann Van Schepdael

ELECTROPHORESIS · 2025

DOI: 10.1002/elps.70040 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ELECTROPHORESIS, 2025. Verfasst von Hailekiros Gebretsadik Kidanemariam und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, KU Leuven-University of Leuven, Leuven, Belgium. Hauptthemen laut MEDLINE: Insulin. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Substandard and falsified medicines pose a significant public health threat, particularly in low‐income countries. Ensuring pharmaceutical quality is crucial to mitigate risks associated with ineffective and harmful medications. Among others, developing and implementing robust and cost‐effective analytical methods is an important and quick strategy for ensuring the quality of medicines. This study aimed to develop a robust and cost‐effective capillary zone electrophoresis method with UV detection for insulin analysis in active pharmaceutical ingredient and formulations. A multilayer capillary coated with polybrene and poly(sodium 4‐styrenesulfonate) improved repeatability. The method was optimized by systematically evaluating running buffer composition, pH, ionic strength, and voltage, achieving optimal separation with a 60 mM phosphate buffer at pH 8.0. It demonstrated excellent precision, accuracy, linearity, and robustness. Application of the method to insulin commercial samples verified compliance with pharmacopoeial standards. The method could be a reliable and accessible alternative for quality control of insulin in resource‐limited settings, supporting efforts to combat substandard pharmaceuticals and protect public health. Moreover, the method aligns with green chemistry principles, as it eliminates the need for organic solvents, either as solvent or as a component of the running buffer.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

InsulinElectrophoresis, CapillaryReproducibility of ResultsQuality ControlLinear ModelsLimit of DetectionPolymersHexadimethrine Bromide

Stichwörter der Autor:innen

capillary coating | capillary zone electrophoresis (CZE)–UV | insulin | quality…

Substanzen

InsulinPolymersHexadimethrine Bromide

Autor:innen und Institutionen

  • Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, KU Leuven-University of Leuven, Leuven, Belgium.
  • Department of Pharmaceutical Analysis and Quality Assurance, College of Health Sciences, School of Pharmacy, Mekelle University, Mekelle, Ethiopia.

Zitieren

APA

Kidanemariam, H. G., Adams, E., & Van Schepdael, A. (2025). A Simple and Affordable CZE–UV Method for Quality Control of Insulin in Active Pharmaceutical Ingredient and Formulations Using Quadruple Polymer‐Coated Capillary. ELECTROPHORESIS. https://doi.org/10.1002/elps.70040

Vancouver

Kidanemariam HG, Adams E, Van Schepdael A. A Simple and Affordable CZE–UV Method for Quality Control of Insulin in Active Pharmaceutical Ingredient and Formulations Using Quadruple Polymer‐Coated Capillary. ELECTROPHORESIS. 2025. doi:10.1002/elps.70040

BibTeX
@article{Kidanemariam2025,
  author = {Kidanemariam, Hailekiros Gebretsadik and Adams, Erwin and Van Schepdael, Ann},
  title = {A Simple and Affordable CZE–UV Method for Quality Control of Insulin in Active Pharmaceutical Ingredient and Formulations Using Quadruple Polymer‐Coated Capillary},
  journal = {ELECTROPHORESIS},
  year = {2025},
  doi = {10.1002/elps.70040}
}
Kostenlos starten →