EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Determination of amphetamine enantiomers in urine by conductive vial electromembrane extraction and ultra‐high performance supercritical fluid chromatography tandem mass spectrometry

Tonje Gottenberg Skaalvik iD, Elisabeth Leere Øiestad iD, Stig Pedersen-Bjergaard, Solfrid Hegstad iD

Drug Testing and Analysis · 2023-08 · 15 (8) · 909-918

DOI: 10.1002/dta.3487 ↗

At a glance

Journal article in Drug Testing and Analysis, published online on 2023-05-10. Written by Tonje Gottenberg Skaalvik and 3 co-authors. Institution: Department of Clinical Pharmacology, St. Olav University Hospital, Trondheim, Norway. Major MEDLINE topics: Amphetamine, Chromatography, Supercritical Fluid. Cited 30 times so far (Crossref); 46 references. The full text is freely available (open access, CC BY 4.0). Funded by: Research Council of Norway, Norges Forskningsråd.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Separation and quantification of amphetamine enantiomers are commonly used to distinguish between consumption of prescription amphetamine (mostly S ‐amphetamine) and illicit forms of the drug (racemate). In this study, electromembrane extraction with prototype conductive vials was combined with ultra‐high performance supercritical fluid chromatography (UHPSFC‐MS/MS) to quantify R ‐ and S ‐amphetamine in urine. Amphetamine was extracted from 100 μL urine, diluted with 25 μL internal standard solution and 175 μL 130 mM formic acid, across a supported liquid membrane (SLM) consisting of 9 μL of a 1:1(w/w) mixture of 2‐nitrophenyloctyl ether (NPOE) and bis(2‐ethylhexyl)phosphite (DEHPi) into an acceptor phase containing 300 μL 130 mM formic acid. The extraction was facilitated by the application of 30 V for 15 min. Enantiomeric separation was achieved using UHPSFC‐MS/MS with a chiral stationary phase. The calibration range was 50–10,000 ng/mL for each enantiomer. The between‐assay CV was ≤5%, within‐assay CV ≤ 1.5%, and bias within ±2%. Recoveries were 83%–90% (CV ≤ 6%), and internal standard corrected matrix effects were 99–105 (CV ≤ 2%). The matrix effects ranged from 96% to 98% (CV ≤ 8%) when not corrected by the internal standard. The EME method was compared with a chiral routine method that employed liquid–liquid extraction (LLE) for sample preparation. Assay results were in agreement with the routine method, and the mean deviation between methods was 3%, ranging from −21% to 31%. Finally, sample preparation greenness was assessed using the AGREEprep tool, which resulted in a greenness score of 0.54 for conductive vial EME, opposed to 0.47 for semi‐automated 96‐well LLE.

Subjects

MeSH terms (MEDLINE)

AmphetamineChromatography, Supercritical FluidTandem Mass SpectrometryFormatesChromatography, High Pressure Liquid

Author keywords

amphetaminechiral chromatographyelectromembrane extractionsample preparationsupercritical fluid chromatography

Substances

Amphetamineformic acidFormates

Authors and institutions

  • Department of Clinical Pharmacology, St. Olav University Hospital, Trondheim, Norway.
  • Department of Pharmacy, University of Oslo, Oslo, Norway.
  • Department of Forensic Sciences, Division of Laboratory Medicine, Oslo University Hospital, Oslo, Norway.
  • Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.

ORCID profiles: Tonje Gottenberg Skaalvik, Elisabeth Leere Øiestad, Solfrid Hegstad

Funding

  • Research Council of Norway
  • Norges Forskningsråd

Cite

APA

Skaalvik, T. G., Øiestad, E. L., Pedersen-Bjergaard, S., & Hegstad, S. (2023). Determination of amphetamine enantiomers in urine by conductive vial electromembrane extraction and ultra‐high performance supercritical fluid chromatography tandem mass spectrometry. Drug Testing and Analysis, 15(8), 909-918. https://doi.org/10.1002/dta.3487

Vancouver

Skaalvik TG, Øiestad EL, Pedersen-Bjergaard S, Hegstad S. Determination of amphetamine enantiomers in urine by conductive vial electromembrane extraction and ultra‐high performance supercritical fluid chromatography tandem mass spectrometry. Drug Testing and Analysis. 2023;15(8):909-918. doi:10.1002/dta.3487

BibTeX
@article{Skaalvik2023,
  author = {Skaalvik, Tonje Gottenberg and Øiestad, Elisabeth Leere and Pedersen-Bjergaard, Stig and Hegstad, Solfrid},
  title = {Determination of amphetamine enantiomers in urine by conductive vial electromembrane extraction and ultra‐high performance supercritical fluid chromatography tandem mass spectrometry},
  journal = {Drug Testing and Analysis},
  year = {2023},
  volume = {15},
  number = {8},
  pages = {909--918},
  doi = {10.1002/dta.3487}
}
Start for free →