Quantitative determination of R/S‐methadone in human serum using ultra‐high performance supercritical fluid chromatography‐tandem mass spectrometry: A method for routine use
Drug Testing and Analysis · 2024
DOI: 10.1002/dta.3693 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Drug Testing and Analysis, 2024. Verfasst von Miriam Hansen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Pharmacology, St. Olav University Hospital, Trondheim, Norway. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Methadone, Chromatography, Supercritical Fluid. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Methadone has two enantiomers, which exhibit differences in pharmacological effects, with R‐methadone being the active and S‐methadone the inactive enantiomer. A robust, simple and rapid method for chiral separation of the two enantiomers in serum samples using ultra‐high performance supercritical fluid chromatography‐tandem mass spectrometry (UHPSFC‐MSMS) has been developed and validated. Enantiomeric separation was achieved using a Chiralpak IH‐3 column with a mobile phase consisting of CO 2 and 30mM ammonium acetate in methanol/water (98/2, v/v). Runtime was 4 minutes. Sample preparation was semi‐automated using a Hamilton ML Star robot with protein precipitation, and phospholipid removal was carried out using a Waters OSTRO™ 96‐well plate. The calibration range was 50.0–1,500 nM for each enantiomer. The between‐assay relative standard deviations were in the range of 1.2–3.6%. Matrix effects ranged from 99% to 115% corrected with internal standard. The method has been implemented in our laboratory and has proven to be a robust and reliable method for determining the ratio of R/S‐methadone in authentic patient samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Pharmacology, St. Olav University Hospital, Trondheim, Norway.
- Department of Clinical and Molecular Medicine, Norwegian University of Science and Technology, Trondheim, Norway.
ORCID-Profile: Miriam Hansen, Trine Naalsund Andreassen, Solfrid Hegstad
Zitieren
APA
Hansen, M., Havnen, H., Andreassen, T. N., Spigset, O., & Hegstad, S. (2024). Quantitative determination of R/S‐methadone in human serum using ultra‐high performance supercritical fluid chromatography‐tandem mass spectrometry: A method for routine use. Drug Testing and Analysis. https://doi.org/10.1002/dta.3693
Vancouver
Hansen M, Havnen H, Andreassen TN, Spigset O, Hegstad S. Quantitative determination of R/S‐methadone in human serum using ultra‐high performance supercritical fluid chromatography‐tandem mass spectrometry: A method for routine use. Drug Testing and Analysis. 2024. doi:10.1002/dta.3693
BibTeX
@article{Hansen2024,
author = {Hansen, Miriam and Havnen, Hilde and Andreassen, Trine Naalsund and Spigset, Olav and Hegstad, Solfrid},
title = {Quantitative determination of R/S‐methadone in human serum using ultra‐high performance supercritical fluid chromatography‐tandem mass spectrometry: A method for routine use},
journal = {Drug Testing and Analysis},
year = {2024},
doi = {10.1002/dta.3693}
}