EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Determination of amphetamine enantiomers in urine by conductive vial electromembrane extraction and ultra‐high performance supercritical fluid chromatography tandem mass spectrometry

Tonje Gottenberg Skaalvik iD, Elisabeth Leere Øiestad iD, Stig Pedersen-Bjergaard, Solfrid Hegstad iD

Drug Testing and Analysis · 2023-08 · 15 (8) · 909-918

DOI: 10.1002/dta.3487 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Drug Testing and Analysis, online erschienen am 10.05.2023. Verfasst von Tonje Gottenberg Skaalvik und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Pharmacology, St. Olav University Hospital, Trondheim, Norway. Hauptthemen laut MEDLINE: Amphetamine, Chromatography, Supercritical Fluid. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Council of Norway, Norges Forskningsråd.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Separation and quantification of amphetamine enantiomers are commonly used to distinguish between consumption of prescription amphetamine (mostly S ‐amphetamine) and illicit forms of the drug (racemate). In this study, electromembrane extraction with prototype conductive vials was combined with ultra‐high performance supercritical fluid chromatography (UHPSFC‐MS/MS) to quantify R ‐ and S ‐amphetamine in urine. Amphetamine was extracted from 100 μL urine, diluted with 25 μL internal standard solution and 175 μL 130 mM formic acid, across a supported liquid membrane (SLM) consisting of 9 μL of a 1:1(w/w) mixture of 2‐nitrophenyloctyl ether (NPOE) and bis(2‐ethylhexyl)phosphite (DEHPi) into an acceptor phase containing 300 μL 130 mM formic acid. The extraction was facilitated by the application of 30 V for 15 min. Enantiomeric separation was achieved using UHPSFC‐MS/MS with a chiral stationary phase. The calibration range was 50–10,000 ng/mL for each enantiomer. The between‐assay CV was ≤5%, within‐assay CV ≤ 1.5%, and bias within ±2%. Recoveries were 83%–90% (CV ≤ 6%), and internal standard corrected matrix effects were 99–105 (CV ≤ 2%). The matrix effects ranged from 96% to 98% (CV ≤ 8%) when not corrected by the internal standard. The EME method was compared with a chiral routine method that employed liquid–liquid extraction (LLE) for sample preparation. Assay results were in agreement with the routine method, and the mean deviation between methods was 3%, ranging from −21% to 31%. Finally, sample preparation greenness was assessed using the AGREEprep tool, which resulted in a greenness score of 0.54 for conductive vial EME, opposed to 0.47 for semi‐automated 96‐well LLE.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AmphetamineChromatography, Supercritical FluidTandem Mass SpectrometryFormatesChromatography, High Pressure Liquid

Stichwörter der Autor:innen

amphetaminechiral chromatographyelectromembrane extractionsample preparationsupercritical fluid chromatography

Substanzen

Amphetamineformic acidFormates

Autor:innen und Institutionen

  • Department of Clinical Pharmacology, St. Olav University Hospital, Trondheim, Norway.
  • Department of Pharmacy, University of Oslo, Oslo, Norway.
  • Department of Forensic Sciences, Division of Laboratory Medicine, Oslo University Hospital, Oslo, Norway.
  • Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.

ORCID-Profile: Tonje Gottenberg Skaalvik, Elisabeth Leere Øiestad, Solfrid Hegstad

Förderung

  • Research Council of Norway
  • Norges Forskningsråd

Zitieren

APA

Skaalvik, T. G., Øiestad, E. L., Pedersen-Bjergaard, S., & Hegstad, S. (2023). Determination of amphetamine enantiomers in urine by conductive vial electromembrane extraction and ultra‐high performance supercritical fluid chromatography tandem mass spectrometry. Drug Testing and Analysis, 15(8), 909-918. https://doi.org/10.1002/dta.3487

Vancouver

Skaalvik TG, Øiestad EL, Pedersen-Bjergaard S, Hegstad S. Determination of amphetamine enantiomers in urine by conductive vial electromembrane extraction and ultra‐high performance supercritical fluid chromatography tandem mass spectrometry. Drug Testing and Analysis. 2023;15(8):909-918. doi:10.1002/dta.3487

BibTeX
@article{Skaalvik2023,
  author = {Skaalvik, Tonje Gottenberg and Øiestad, Elisabeth Leere and Pedersen-Bjergaard, Stig and Hegstad, Solfrid},
  title = {Determination of amphetamine enantiomers in urine by conductive vial electromembrane extraction and ultra‐high performance supercritical fluid chromatography tandem mass spectrometry},
  journal = {Drug Testing and Analysis},
  year = {2023},
  volume = {15},
  number = {8},
  pages = {909--918},
  doi = {10.1002/dta.3487}
}
Kostenlos starten →