EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effects of 5 Nanosilica Concentrations and Humid Environments at 6 Different pH Levels on Fracture Toughness and Moisture Absorption of Dental Polymethyl Methacrylate Resin‎ Reinforced With Silica Nanoparticles: An Explorative Experimental Scanning Electron Microscopy Study

Mohammad Ali Golshokouh iD, Nima Refahati iD, Pouyan Roodgar Saffari iD

Clinical and Experimental Dental Research · 2024

DOI: 10.1002/cre2.70006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical and Experimental Dental Research, 2024. Verfasst von Mohammad Ali Golshokouh und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Damavand Branch, Islamic Azad University, Damavand, Iran. Hauptthemen laut MEDLINE: Silicon Dioxide, Nanoparticles, Polymethyl Methacrylate, Microscopy, Electron, Scanning. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: This study is Self-funded..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

No study has assessed the effects of nanosilica within polymethyl methacrylate (PMMA) resin and environmental pH on resin's fracture resistance and moisture absorption.

Methods

A total of 90 specimens were divided into 30 subgroups of three, as per the ASTM D5045 standard: five groups of nanosilica percentages (0%/2%/5%/7%/10%), each ‎divided into six subgroups of pH levels (pH = 5/6/7/8/9, + “dry” control). The specimens were prepared by mixing silica nanoparticles with PMMA powder in a vacuum mixer. Then, the specimens were mixed with a diluent liquid (TEGDMA) according to the manufacturer's instructions. For each of the five weight percentages, 36 samples were produced. The 18 specimens in each group were randomly divided into six subgroups of pH levels. The specimens were kept in containers of liquid at different pH levels at room temperature for 1 week. Their before‐ and after‐storage weights were recorded to calculate moisture absorption. The fracture resistance test was performed (ASTM D5045 standard) using the three‐point bending method. Scanning electron microscopy was performed. Data were analyzed.

Results

Both nanosilica extents and pH levels significantly affected the fracture toughness with a significant interaction ( p < ‎‎0.00001). All post hoc comparisons of different pH levels (except pH= 5 vs. 6) were significant ( p < ‎‎0.0001). All post hoc comparisons of different nanosilica concentrations were significant ( p < ‎‎0.0001). Both nanosilica extents and pH levels significantly influenced the fracture toughness with a significant interaction ( p < ‎‎0.00001). All post hoc comparisons of different pH levels and also between different nanosilica concentrations were significant ( p < ‎‎0.0001). The correlation between moisture absorption and fracture toughness was significant ( R = −0.382, p = 0.0009).

Conclusions

Fracture toughness decreases when placed in humid and acidic environments. Also, the samples that were placed in a humid environment suffered a brittle fracture. Increasing silica nanoparticles improved fracture toughness (becoming optimal at 5 wt% nanosilica). Objective and Materials The objective of this study was to investigate the fracture toughness of dental samples made of PMMA reinforced with various percentages of nanosilica at various pH levels. For this purpose, dental resins with various amounts of nanosilica were placed in moist media at different pH values ranging from 5 to 9 (mimicking the normal pH range of the human mouth).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Silicon DioxideNanoparticlesPolymethyl MethacrylateMicroscopy, Electron, ScanningMaterials TestingHumidityHydrogen-Ion ConcentrationDental MaterialsSurface PropertiesDental Stress AnalysisHumansWater

Stichwörter der Autor:innen

dental materialsfracture resistancemoisture absorptionnanomaterialsnanosilicapolymethyl methacrylate (PMMA)scanning electron microscopysilicon nanoparticles

Substanzen

Silicon DioxidePolymethyl MethacrylateDental MaterialsWater

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Damavand Branch, Islamic Azad University, Damavand, Iran.
  • Department of Civil Engineering, Thammasat School of Engineering, Faculty of Engineering, ‎Thammasat University, Pathumthani, Thailand.

ORCID-Profile: Mohammad Ali Golshokouh, Nima Refahati, Pouyan Roodgar Saffari

Förderung

  • This study is Self-funded.

Zitieren

APA

Golshokouh, M. A., Refahati, N., & Saffari, P. R. (2024). Effects of 5 Nanosilica Concentrations and Humid Environments at 6 Different pH Levels on Fracture Toughness and Moisture Absorption of Dental Polymethyl Methacrylate Resin‎ Reinforced With Silica Nanoparticles: An Explorative Experimental Scanning Electron Microscopy Study. Clinical and Experimental Dental Research. https://doi.org/10.1002/cre2.70006

Vancouver

Golshokouh MA, Refahati N, Saffari PR. Effects of 5 Nanosilica Concentrations and Humid Environments at 6 Different pH Levels on Fracture Toughness and Moisture Absorption of Dental Polymethyl Methacrylate Resin‎ Reinforced With Silica Nanoparticles: An Explorative Experimental Scanning Electron Microscopy Study. Clinical and Experimental Dental Research. 2024. doi:10.1002/cre2.70006

BibTeX
@article{Golshokouh2024,
  author = {Golshokouh, Mohammad Ali and Refahati, Nima and Saffari, Pouyan Roodgar},
  title = {Effects of 5 Nanosilica Concentrations and Humid Environments at 6 Different pH Levels on Fracture Toughness and Moisture Absorption of Dental Polymethyl Methacrylate Resin‎ Reinforced With Silica Nanoparticles: An Explorative Experimental Scanning Electron Microscopy Study},
  journal = {Clinical and Experimental Dental Research},
  year = {2024},
  doi = {10.1002/cre2.70006}
}
Kostenlos starten →